Preparation

This section describes the setting method based on preliminary examination. Perform a test to
check whether the intended code is read and set the reading conditions for the purpose.
Testing
You can check how stably the intended code can be read.
Read the code at rest ten times and calculate the reading rate.
Entering the reading rate measurement mode
1.
Place the code in the reading position.
2.
Input the command "[XU8".
The reader enters the reading rate measurement mode.
The reading rate in every 10 reading operations is measured.
3.
To exit the reading rate measurement mode, restart the reader.
The reader returns to the normal measurement mode.
Do not execute write command "Z2" to nonvolatile memory.
A sample setting condition is overwritten and stored, which erases the already set reading condition.
Output format
In reading rate measurement mode, the reading rate in every 10 reading operations is
output continuously to the upper equipment.
10/10
ABCDEFG
Communication data format
Header
Correct
Header
reading data
Footer
The number of times of successful decoding (no verification)
10 reading tries
Correct reading data
Footer
Section 2
Introduction Procedure
Footer
V400-R2 series
User's Manual
37