Omron V400-R2 Series User Manual page 13

Ultra small multi-code reader
Hide thumbs Also See for V400-R2 Series:
Table of Contents

Advertisement

Page format
Preparation
This section describes the settin g method based on preliminary examination. Perform a test to
check whether the intended code is read and set the reading conditions for the purpose.
Testing
You can check how stably the intended code can be read.
Read the code at rest ten times and calculate the reading rate.
Entering the reading rate measurement mode
1.
Place the code in the reading position.
2.
Input the command "[XU8".
The reader enters the reading rate measurement mode.
The reading rate in every 10 reading operations is measured.
3.
To exit the reading rate measurement mode, restart the reader.
The reader returns to the normal measurement mode.
Do not execute write command "Z2" to nonvolatile memory.
A sample setting condition is overwritten and stored, which erases the already set reading condition.
Output format
In reading rate measurement mode, the readi ng rate in every 10 reading operations is
output continuously to the upper equipment.
The number of times of successful decoding (no verification)
10 reading tries
10/10
ABCDEFG
Correct reading data
Communication data format
Header
Correct
Header
Footer
reading data
Footer
Operation procedure and additional explanation
Shows the operation procedure.
Tips and reference pages that may be useful during operation are indicated with a mark.
Section 2
Introduction Procedure
Footer
V400-R2 series
35
User's Manual
Introduction
Title of each section
Overviews and points
Index label
Indicates the current section and the
title of the section.
You can quickly reach the page
containing the information you need.
Illustration
* This page does not actually exist.
V400-R2 series
User's Manual
11

Advertisement

Table of Contents
loading

Table of Contents