Operational Check Of Lcd (Function Code 12) - Brother DCP-9055CDN Service Manual

Color laser mfc
Hide thumbs Also See for DCP-9055CDN:
Table of Contents

Advertisement

1.4.7

Operational check of LCD (Function code 12)

<Function>
This function allows you to check whether the LCD on the control panel works normally.
<Operating procedure>
(1) Press the 1 and 2 buttons in this order in the initial state of the maintenance mode.
The LCD shows.
(2) Each time you press the Start/Black button, the LCD cycles through the displays as
shown below.
(3) When the Stop/Exit button is pressed regardless of the display, the machine cancels the
operation, beeps for one second and returns to the initial state of the maintenance mode.
.
<Display 1>
Backlight
LCD
Data LED
Error LED
<Display 2>
Backlight
LCD
Data LED
Error LED
<Display 3>
Backlight
LCD
Data LED
Error LED
<Display 4>
Backlight
LCD
Data LED
Error LED
: ON
: Display of all dots OFF
: ON
: ON
: ON
: Display of all dots ON
: ON
: ON
: OFF
: Display of all dots OFF
: ON
: ON
: OFF
: Display of all dots ON
: ON
: ON
5-16
Display 1
Display 2
Display 3
Display 4
Fig. 5-7