The Usb Direct Interface Does Not Work (Error Code Ca, Etc); The Room Temperature Is High Or Low; The Specified Tray Is Incorrect - Brother DCP-9055CDN Service Manual

Color laser mfc
Hide thumbs Also See for DCP-9055CDN:
Table of Contents

Advertisement

3.13.3 The USB direct interface does not work (Error code CA, etc)

<User Check>
- Check if the data is supported device.
- Replace the USB memory and check if the interface works.
- Turn OFF and ON the power.
Step
1
2
3

3.13.4 The room temperature is high or low

<User Check>
- Adjust the room temperature to 10 °C to 30 °C.
- Check if the exhaust opening is blocked.
Step
1
2
3

3.13.5 The specified tray is incorrect

<User Check>
- Specify the tray correctly.
Step
1
Cause
Harness connection failure of
USB host relay PCB
USB host relay PCB failure
Main PCB failure
Cause
Internal temperature
thermistor failure
External temperature/
humidity sensor failure
Main PCB failure
Cause
Main PCB failure
Check the harness connection of the USB
host relay PCB ASSY and reconnect it.
Replace the USB host relay PCB ASSY.
Replace the main PCB ASSY.
Replace the Internal temperature thermistor.
Replace the high-voltage power supply PCB
ASSY.
Replace the main PCB ASSY.
Replace the main PCB ASSY.
2-139
Remedy
Remedy
Remedy
Confidential