INSTALLATION
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your stove,
ensure that the clearances are met as
outlined on page 9.
2) Provide adequate clearances for servic-
ing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed on
carpeting, combustible linoleum tile or other
combustible material other than wood fl oor-
ing, the appliance must be installed on a
metal or wood panel extending the full width
and depth of the appliance.
4) The Room Sealed Gas Fireplace can be
installed as follows:
Model #
Position
A)
P121: See Thru
B)
P131: Pier
C)
P121LC: Left Corner
D)
P121RC: Right Corner
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P121/P121LC/P121RC/P131 Room
Sealed Gas Fireplace is approved for alcove
installations, which meet the clearances
listed on this page.
7) We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and fl oor protection before
actually installing this appliance. Have a
authorized inspector, dealer, or installer
review your plans before installation.
Note: For Exterior Flue Termination
Locations see page 12.
.
8
A) P121 - See Thru
B) P131 - Pier
C) P121LC - Left Corner
D) P121RC - Right Corner
®
Regency
P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace