Converion To Lpg - Regency P121-NG Owners & Installation Manual

Zero clearance room sealed gas fireplace
Table of Contents

Advertisement

INSTALLATION
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each LPG Conversion Kit
contains:
Qty.
Part #
Description
1
904-529
5/32" Allen Key
1
904-641
Burner Orifi ce #50
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1
910-037
LPG Injector
(Pilot Orifi ce)
1
918-549
Instruction Sheet
Installation of LPG
Conversion Kit:
1) Remove the louvers and trim kit. Remove
the front door.
2) Remove the logs, embers.
3) Remove the grate by lifting straight up.
Remove the side brick panels (if
installed). The brick panel is very
fragile - handle with care.
22
Conversion Kit #360-968 from NG to LPG
4) Remove the burner assembly by remov-
ing the 4 Phillips head screws and then
slide the burner assembly away from the
orifi ce and lift out (refer to Diagrams 1 and
2).
Diagram 1
Diagram 1 and 2: Remove the left and right
screws and then slide the burner assembly
away from the orifi ce and lift out.
Diagram 2
5) Remove pilot inner
box by removing the
2 screws.
6) Pull off the pilot
cap to expose
the pilot orifi ce.
®
Regency
P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
7) Unscrew the pilot orifi ce with the allen key
and replace with the LPG pilot orifi ce in
the kit and replace pilot cap.
8) Re-install pilot inner box using 2 screws.
9) Remove burner orifi ce with a 1/2" spanner
and discard. Use another spanner to hold
on to the elbow behind the orifi ce.
Burner Orifi ce
10) Reinstall new burner orifi ce LPG stamped
#50 and tighten.
11) Turn control knob to
the "OFF" position.
12) Remove the black
protection cap by hand
from the high-low knob
(Fig.1).
13) Insert a 5/32" or 4mm
Allen wrench into the
hexagonal key-way of
the screw
(Fig. 2), rotate it
counter-clockwise until
it is free and extract it.
Fig. 1
Fig.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents