Remote Control (Optional); Remote Wall Switch (Optional); Wall Thermostat (Optional); Wall Switch - Regency P121-NG Owners & Installation Manual

Zero clearance room sealed gas fireplace
Table of Contents

Advertisement

INSTALLATION
Option 1:
REMOTE CONTROL
®
Use the Regency
Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace
to that location. Use the Thermostat Wire
Table.
2) Connect the two wires to the gas valve. See
diagram below.
CAUTION
Do not connect millivolt remote
control wires to a 240V wire.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
28
Option 2:

WALL SWITCH

1) Run the supplied 4.5m of wire through the
back gas inlet opening. Be careful not to
damage wire.
Note: We recommend a maximum of 4.5m
of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.
2) Connect the wire to the supplied wall switch
and install into the receptacle box.
CAUTION
Do not connect millivolt
wall switch wire to a 240V wire.
®
Regency
P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace
Option 3:
WALL THERMOSTAT
A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use the table below to determine the maximum
wire length.
Note: Preferable if the thermostat is installed
on an interior wall.
®
Regency
offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not connect millivolt
wall thermostat wires
to a 240V wire.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
15.0 M.
14 GA.
10.0 M.
16 GA.
6.0 M.
18 GA.
3.6 M.
20 GA.
2.7 M.