Wiring Diagram - Regency P121-NG Owners & Installation Manual

Zero clearance room sealed gas fireplace
Table of Contents

Advertisement

No electrical power supply is required for the
gas control to operate.
Lockwasher
Star washer
#8 Ground Lug
(for mobile home)
Nut
Ground Wire
Grounding Lug Detail
ON
Burner
Orange
OFF
Yellow
CAUTION:
Label all wires
prior to disconnection when
servicing controls. Wiring er-
rors can cause improper and
dangerous operation.
®
Regency
P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

WIRING DIAGRAM

(Do not cut the ground terminal off under
any circumstances.)
Pilot
Assembly
DC Spark
Box
Ground
(To THTP)
(To TH)
ON OFF
Remote Receiver
Remote Transmitter
or Thermostat
(Millivolt) (Optional)
ON-OFF SWITCH
(910-138) BLACK
~
910-610 BLACK
910-802 BLACK
Brown
White
To Thermocouple IN
(Optional)
Terminal Block Location
Remove cover to ac-
cess Terminal Block
INSTALLATION
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
1
WHITE
FAN 1
TERMINAL
BLOCK
(WIRE SUPPLY & INSTALL BY OTHERS)
BLACK
CONVECTION AIR
TEMPERATURE SWITCH
(THERMO DISC - NORMALLY OPEN)
"S.I.T" Valve
Terminal Block
FAN 2
2
Gas
In
29