Ricoh B039 Service Manual page 159

Gestetner, lanier, ricoh, savin mfp
Table of Contents

Advertisement

USING SERVICE PROGRAM MODES
5
Mode Number/Name
501*
PM Alarm Mode
1
Interval
2
On/Off
801
Memory All Clear
802
Scanner/Printer Free Run
803
Input Check
804
Output Check
807*
Display Language Group
809*
mm/inch Selection
B039/B040/B043
Function/[Setting]
Sets the base PM interval.
[1 ~ 255 / 60 / 1K copies/step]
The value stored in this SP is used when the value of
SP5-501-2 is "1".
Enables/disables the PM alarm for the total number of
prints, copies, and faxes.
[0 = No / 1 = Yes]
Resets all software counters and returns all modes and
adjustments to their defaults settings (except for some
settings, such as SP5-811, SP5-907, SP5-916, and SP7-
003 – ☛ 5.1.8 Memory All Clear for a full list).
[0 = No / 1 = Yes]
• After selecting "1", press the Original Type key and the
' key at the same time to execute the clear. If the clear
is successful, the display shows "Action completed". If
the clear fails, the display shows "Error!!!".
• This SP mode should be used only after replacing the
NVRAM or when the copier has malfunctioned due to
damaged NVRAM.
☛ 5.1.8 Memory All Clear
Starts a free run of both the scanner and the printer.
[0: = No / 1 = Yes]
After selecting "1", press the OK key or ' key twice to
start the run. Press % to stop the free run.
Displays the signals being received from sensors and
switches.
Press ! to exit the program.
☛ 5.1.3 Input Check
Turns on electrical components individually for test
purposes.
☛ 5.1.4 Output Check
Selects the display language group.
[0 = Standard / 1 = Option 1 / 2 = Option 2]
The actual display language can be selected using User
Tools: [6. Language]
Selects whether the display shows values in mm or
inches.
[North Am.: 0 = inch / 1 = mm]
[EU/Asia:
0 = mm / 1 = inch]
5-18