Technical Data - Xth - Studer XTH 3000-12 User Manual

Unit combining inverter, battery charger and transfer system
Table of Contents

Advertisement

STUDER Innotec
Xtender
18 TECHNICAL DATA – XTH
**** concerns -01 model (120Vac range) (for all models except the XTH 8000-48)
Model
Inverter
Rated battery voltage
Input voltage range
Continuous power @ 25 °C
Smart boost power
30 minute load @ 25 °C
5 second load @ 25 °C
Maximum load
Maximum asymmetrical load
Load detection (standby)
Admissible cos phi
Maximum efficiency
Open-circuit power
OFF/standby/ON
Output voltage
Output frequency
Harmonic distortion
Overcharge and short-circuit
Overheating protection
Battery charger
6-phase battery charger
Adjustable charge current
Input current limit
Maximum input voltage
AC input voltage range
Admissible input frequency
(PFC)
Battery control (factory value / adjustable range with RCC-02)
End of absorption
Absorption voltage
Periodic absorption voltage
Floating voltage
Reduced maintenance voltage
Equalisation
End of equalisation
Equalisation voltage
Low voltage disconnection
Reduced floating duration
Periodical absorption
Temperature compensation
42
XTH 3000-12
XTH 5000-24
12 V
24 V
9.5 - 17 V
19 - 34 V
2500 VA
4500 VA
3000VA
5000 VA
3000 VA
5000 VA
3 x Pcont
Up to short-circuit
Up to Pnom
2 to 25 W
0.1 – 1
93%
94%
1.2W/2.2W/
1.3W/2.5W/
14W
18W
Sin wave 230Vac (+/-2%) / 180-245 Vac ou
****Sin wave 120 Vac (+/-2%) / 50-140 Vac
50 Hz adjustable 45-65 Hz +/- 0.05% (quartz-controlled)
****60 Hz adjustable 45-65 Hz +/- 0.05% (quartz-controlled)
<2%
Automatic disconnection then 2 startup attempts
Alarm prior to disconnection and automatic restart
Programmable I-U-Uo-equalisation-Uo(low)-U(periodic)
0 - 160 A
0 - 140 A
1 - 50 A
265Vac / ****150Vac
Level detection adjustable from 150 to 230 Vac
****Level detection adjustable from 50 to 140 Vac
45 - 65 Hz
EN 61000-3-2
by duration: 2h / 0.25 - 18 h or by current <10A / 2 - 50 A
14.4V /
28.8V /
9.5-17 V
19-34 V
- / 9.5 - 17 V
- / 19 - 34 V
13.6V /
27.2V /
9.5-18 V
19-34 V
- / 9.5 - 17 V
- / 19 - 34 V
By number of cycles ( - / - 100) or at fixed intervals ( - / 52
weeks)
By duration 2h / 0.25 – 10h or by current - / 5 – 50 A
- / 9.5 - 17 V
- / 19-346 V
10.8V /
21.6V /
9.5-17 V
19-34 V
- / 0 - 32 days
- / 0 - 10 hours
-5 / 0 to-8 mV/°C/cell (optional BTC-01)
V.3.1.0
XTH 6000-48
XTH 8000-48
48 V
48 V
38 - 68 V
39 - 68 V
5000 VA
7,000 VA
6000 VA
8000 VA
6000 VA
8000 VA
96%
96%
1.8W/3W/
1.8W/3.8W/
22W
26 W
0 - 100 A
0 - 120 A
57.6V / 38 - 68 V
- / 38 - 68 V
54.4V / 38 - 68 V
-- / 38 - 68 V
- / 38 - 68 V
43.2V / 38 - 68 V
User manual