Control And Display Parts For The Xtender (Fig. 4B) - Studer XTH 3000-12 User Manual

Unit combining inverter, battery charger and transfer system
Table of Contents

Advertisement

STUDER Innotec
Xtender
Pos.
Denomination
13
AC Input
14
AC Output
17
--
18
--
19

15 CONTROL AND DISPLAY PARTS FOR THE XTENDER (FIG. 4B)

See chapter 7.2 - p. 29.
Pos.
Denomination
41
42
OFF
43
ON
44
Charge
45
AC in
38
Description
Connection terminals for the
alternative
power
(generator or public network)
Connection terminals for the
device output.
Supplementary
terminal
protective earth
Mounting hook-up
Access
shutter
to
fastening screw.
Description
Comments
ON/OFF button
The ON/OFF button allows the start up or complete
stoppage of the system such as it has been
programmed. When there are several units in the
same system, each unit must be started up or
stopped individually using this button.
Light indicator
When the light indicator flashes it indicates the cause
for
stoppage
of the stoppage of the unit, its imminent stoppage or
of the unit
the limitation of its rated power output according to
chapter 7.2 - p.29.
Light indicator
This indicator is glowing continuously when the
showing
that
device is working. It flashes when the equipment is at
the equipment
a temporary stop. Note: The equipment will restart
is in operation
automatically when the conditions that led to the
temporary stoppage have gone away.
Light indicator
This indicator is glowing continuously when the
showing
that
charger is in operation and has not yet reached the
the battery is
absorption phase.
being charged
It flashes twice during the absorption phase and
once during the maintenance phase.
If smart boost mode has been activated it is possible
that this indicator will go out temporarily when source
backup is required by users. (See chapter
)
23
Light indicator
This indicator is glowing continuously when an
showing
the
alternative voltage with correct values is present at
presence
of
the AC IN input (13) of the device and the current
correct
and
limit {1107) set by the user has not been reached. It
synchronised
flashes when this limit is reached (see chapter 6.2.5 –
input voltage
p. 23).
V.3.1.0
Comment
See chapter 4.5.7 - p. 17.
supply
Note: It is imperative that the PE
terminal be connected.
See chapter 4.5.6 - p. 17.
Note: Increased voltages may appear
on the terminals, even in the absence
of voltage at the input of the inverter.
for
This terminal can be used if the
required earth cable cross-section is
too big to be connected in the
terminal 13 or 14
the
top
Full tightening of the top fastening
screw may be required in mobile
application or in case of heavy
vibration
apparatus.
of
the
support
of
6.2.6
User manual
the
- p.

Hide quick links:

Advertisement