4.1.3
Locating the defective component
After determining the error class by the CSS or Global Error indicators (see
section
4.1.2 on page
system board allow you to identify the defective component.
I
For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual available from the ServerView Suite DVD 2
supplied with your PRIMERGY server or online at
http://manuals.ts.fujitsu.com
http://jp.fujitsu.com/platform/server/primergy/manual/
4.1.3.1
Local diagnostic indicators on the front
Figure 6: Local diagnostic indicators on front panel
Ê Check the CSS indicator on the front and connector panels of the server:
Indicator
HDD / SSD
1
error indicator
PSU error
2
indicator
Temperature
3
error indicator
CPU error
4
indicator
TX300 S7 / RX350 S7
63) local diagnostic indicators on the front panel and
(EMEA market) or
Status
orange on
orange on
orange on
orange on
Upgrade and Maintenance Manual
Basic hardware procedures
Description
HDD / SSD, SAS / SATA backplane or
RAID controller failure detected
Hot-plug PSU module failure detected
I
Only available in redundant
PSU configurations
Operating temperature levels above
permitted limits
CPU prefailure event detected
(Japanese market).