Precor P10 Operating And Maintaining page 24

Precor p10 console operating and maintaining
Hide thumbs Also See for P10:
Table of Contents

Advertisement

22
Set Max Workout Time (All Equipment)
Value Range: 1 to 240 minutes
(Default: 60 minutes)
You can set a maximum workout time per session. Choose a
time limit between 1 and 240 minutes, or select No Limit if
you do not want to set a time limit. For example, if you set the
time limit to 20 minutes, users can only enter a workout time
between 1 and 20 minutes.
Set Max Pause Time (All Equipment)
Value Range: 1 to 120 seconds
(Default: 120 seconds)
This setting limits how long equipment remains in a paused
banner during a workout before it resets.
Note: The optional power adapter must be connected on
self-powered equipment to establish a definitive pause time
limit. If the optional power adapter is not attached and the
rate of motion drops below the minimum requirements, the
equipment begins its shutdown, effectively eliminating pause
mode.
Set Cool Down Time (All Equipment)
Value Range: 0 to 5 minutes
(Default: 5 minutes)
Select the maximum amount of time the equipment remains
in the cool down mode. The cool down time is the period of
time following the completion of a program when the user
exercises at a reduced work rate.
Operating and Maintaining the P10 Console

Advertisement

Table of Contents
loading