5. SERVICE PROGRAMME
Function
TOTAL WATER....S2
(ml)
Number
WATER DESCALING
S2
(ml)
HOT WATER
FLOW (l/h) 20
(Only in System 2: OFF
for Royal Cappucc.)
HOT WATER
PUMP ADJUST. 63000
(Only in System 2: OFF
for Royal Cappucc.)
TURBOWATER
FLOW (l/h) 20
(Only in System 2: ON)
only Royal Cappucc.)
TURBOWATER
PUMP ADJUST. 63000
(Only in System 2: ON)
(only Royal Cappucc.)
WATER RESERVE
NUMBER
No. of PULSES
NUMBER
From Version: 2003
Page 12/24
Setting range
Increment
6 – 34 1/h
58,000 - 65,500
6 - 34 1/h
58,000 - 65,500
1-2500
REV.4 SEPT.2003
Comments
Pump system 2
Total water flow volume (in ml) /
not resettable
Pump system 2:
Total water flow (in ml) since last
descaling.
Reset: See S1
+/- 2 1/h
The pump delivery rate for hot
water can be expressed in litres per
hour.
+/- 1
The pump delivery rate is adjusted
in relation to the HOT WATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under HOT WATER PUMP
ADJUSTMENT.
+/- 2 1/h
The pump delivery rate for
turbowater can be expressed in
litres per hour.
(only active when System 2 steam
cycle is active; mixes with hot
water System 1 and System 2)
+/- 1
The pump delivery rate is adjusted
in relation to the TURBOWATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under TURBOWATER
PUMP ADJUSTMENT.
Only when System 2 is activated.
When the water tank is full, the
value from WATER RESERVE
STOP is applied. The flow meter
pulses are counted from when the
reed switch is switched and
deducted from the value. If a
beverage is chosen for which the
saved pulse number is higher than
the remaining pulses, the message
FILL WATER TANK appears.