Saeco Classic Service Manual page 56

Coffee machine
Table of Contents

Advertisement

4. FUNCTION/TIMING
Component
14
Sensor (KTY)
Pipe heating
15
Pipe heating thermostat
16
Valve plug
17
Valve (for boiler filling)
18
Valve (Cappumore)
19
Valve (steam)
20
Valve (water)
Note:
In the Royal Coffeebar it is possible to operate the machine directly from the fixed water
connection. The inlet valve is activated via the user programme (Chap. 3, Page 16).
A pressure reducer installed at the inlet point maintains an almost pressureless operation before
the pump.
However, a separate flow meter is used to measure the flow rate.
Page 10/22
Transmits current temperature value to electronic
system
Alternates current supply for heating system in event
of overheating.
Opens when brewing unit is aligned with water circuit
to the unit itself.
Solenoid valve for filling pipe heating system
Solenoid valve/steam dispensing for Cappumore
For hot water and steam dispensing
Solenoid valve for water dispensing
REV.4 SEPT.2003
ROYAL
Function
Saeco International Group

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents