ROYAL
13
Sensor (KTY)
System 2 (steam)
14
Thermostat
System 2 (steam)
15
Boiler pin (Valve plug)
16
Steam valve
17
Valve cappuccinatore
(for cappuccino maker)
18
Valve (water)
19
Valve (steam)
Saeco International Group
Component
REV.4 SEPT.2003
4. FUNCTION/TIMING
Transmits current temperature value to electronic
system
Alternates current supply for heating system in event
of overheating.
Opens when brewing unit is aligned with water circuit
to the unit itself.
For steam dispensing
Solenoid valve/steam dispensing for cappuccino
Solenoid valve for water dispensing
Solenoid valve for steam dispensing (turbowater)
Function