Trans Current
2301
Adjusts the correction current applied to the transfer roller.
Trans (1)
2301 1
Adjusts the correction value for the transfer current in 120.8 mm/sec line
speed.
Trans (2)
2301 2
Adjusts the correction value for the transfer current in 161.4 mm/sec line
speed.
Thermistor Adjust
2910
If this is "Yes", the machine automatically adjusts the charge roller voltage
and transfer current in response to the temperature within the machine.
PreRotate Time
2911
Curl Reduction
2911 2
Specifies the pre-rotation time at power-on or recovery from the energy
saver mode.
LowTemp PreRotate
2911 3
Specifies the pre-rotation time at power-on or recovery from the energy
saver mode in low temperature environment (less than -15°C).
Waste Toner Count
2980
Displays the waste toner counter in the engine board.
SM Appendix
CÓPIA NÃO CONTROLADA
[-5 to 5 / 0 / 1
[-5 to 5 / 0 / 1
0: Yes, 1: No DFU
[0 to 40 / 20 / 5 sec/step]
[0 to 40 / 20 / 5 sec/step]
3-17
CÓPIA NÃO CONTROLADA
SP Tables
A/step]
A/step]
M047