Xcp Issues Fixed In Xcp 1091 - Fujitsu SPARC Enterprise M4000 Product Notes

Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

Known Issues and Workarounds in XCP 1091 (Continued)
TABLE 4
ID
Description
RTIF1--
When you use the setnameserver(8)
091109-003
command or the DNS setting of XSCF Web to
register the DNS server or the search path, you
can specify two or more same IP address
values or domain names.
However, when you specify two or more same
IP address values or domain names to delete
all the DNS servers or the search paths which
are same, it returns an invalid parameter.
RTIF1-
When you start up a domain from a disk
091109-004
connected to the 8-Gbps fibre channel card
(SE0X7F21F, SE0X7F22F), if you fail to specify
the correct device path, an error log with no
message might be registered.
In the same way, when you start up a domain
from a disk connected to the 8-Gbps fibre
channel card (SE0X7F21F, SE0X7F22F), even if
the domain cannot be started due to reasons
such as disk failure, the error log might not be
registered.
RTIF1-
The loadcert console operand is missing in
091105-001
the usage of the setad(8) command and the
setldapssl(8) command.

XCP Issues Fixed in XCP 1091

TABLE 5
XCP issues Fixed in XCP 1091
TABLE 5
ID
Description
RTIF1-
While XSCF is running, a process may go
070418-009
down, a watchdog timeout may occur, or a
hang-up may occur. After this, XSCF may
reset.
RTIF1-
While XSCF is running, watchdog timeout
070528-002
may occur and XSCF may reboot.
20
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1091 • April 2010
lists XCP issues fixed in XCP 1091.
Workaround
To delete all the DNS servers or the search
paths which are same, specify just one
corresponding address or domain name.
In doing so, all the DNS servers or the search
paths which are same will be deleted. Register
the data again as needed.
No workaround is available.
For how to use the loadcert console
operand of the setad(8) command and the
setldapssl(8) command, see the manual
page.
Workaround
Check that XSCF is started. If not started, stop
all the domains and then execute the system
power off/on (AC OFF/ON). To turn on the
system power that you turned off, wait at least
30 seconds before power-on.
Check that XSCF is started. If not started, stop
all the domains and then execute the system
power off/on (AC OFF/ON). To turn on the
system power that you turned off, wait at least
30 seconds before power-on.

Advertisement