XCP Issues Fixed in Releases Earlier Than XCP 1091 (Continued)
TABLE 6
ID
Description
RTIF1-
On the cluster system using the
080808-001
PRIMECLUSTER software, when there are 10
or more RCI units, the RCI busy status may be
temporarily unreleased and output the
following syslog message:
SA_pprcir.so to test host host_name
failed
RTIF1-
The error log "XSCF FMEM write error"
081006-001
recorded and the firmware update might fail.
RTIF1-
In the setemailreport(8) command, when
081006-002
you specified over 255 characters in the SMTP
address, an error results.
RTIF1-
During the firmware update, there might be
081006-004
the following output message and a XSCF
panic might occur.
kernel BUG in jffs2_do_read_inode
at fs/jffs2/readinode.c:XXX!
RTIF1-
The network configuration on the XSCF Web
081006-005
does not support the function equivalent to the
setnetwork -r comand. And when you
specified localhost or localdomain to the host
name or the domain name, the error message
"SessionID has expired" appears.
RTIF1-
The panic log on the XSCF Web might not be
081006-006
displayed from the top of the message.
RTIF1-
The password(8) command indicates that the
081006-007
[user] operand is optional but will fail if a
[user] operand is not included when other
options are specified.
RTIF1-
Power failure at the commercial AC supply
081016-001
connector to the UPS does not send
notification/send trap.
RTIF1-
In Internet Explorer 6 or 7, clicking on the
081016-003
[Reset] button then the [OK] button from the
Settings->Audit->Add Policy poupup screen
will log the user out with message:
Error
Session Error
Session ID has been expired 
32
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1091 • April 2010
Workaround
Refer to the manual of the PRIMECLUSTER
software to check the cluster status. If no
problem found on the status, this message can
be safely ignored. If any problem, follow the
instructions on the manual to solve the
problem.
Power off (AC OFF) the system, and power on
(AC ON) again. Then, re-execute the firmware
update.
Do not specify over 255 characters in the SMTP
address.
Reset XSCF and use the flashupdate(8)
command to retry the firmware update.
Use the setnetwork -r command on the
XSCF shell.
When the output is insufficient, execute the
showlogs panic command on the XSCF shell.
No workaround is available.
Specify the user operand to execute the
password(8) command when you specify
other options.
No workaround is available.
Log back into the browser interface and use
the backspace key to clear text in the 'User'
text box of the popup screen instead of using
the Reset button.