Fujitsu SPARC Enterprise M4000 Product Notes page 34

Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

XCP Issues Fixed in Releases Earlier Than XCP 1091 (Continued)
TABLE 6
ID
Description
RTIF1-
On the Domain Configuration screen, when
070824-008
you select an undefined Domain ID, the
Configuration Policy remains as the content
which previously displayed.
RTIF1-
On the System Board Configuration screen,
070824-009
when you execute Detail, it is displayed as if
the CPUM and the memory of MBU are all
mounted on the PSB#0 side. And in the detail
display of PSB#0, memory is displayed as "22
+ 2."
RTIF1-
While using Firefox 2, in the Configuration
070824-011
policy setting on the Domain Configuration
screen, when you specify a domain which is in
operation, an error display pop-up appears.
When you click on the Back button on this
error display pop-up and click on the Cancel
button on the inquiry screen to re-display the
data, the system remains in the error message
screen.
RTIF1-
When the snapshot CLI attempts to write to a
070904-002
USB stick that has write protect set results in
an I/O error.
RTIF1-
An incorrect domain state is reported. After
070904-003
the command sendbreak(8) to domain is
issued, showdomainstatus(8) continues to
show the state as "Running" when the domain
is actually at "ok" prompt.
RTIF1-
Time can't be synchronized with the NTP
070904-005
server.
RTIF1-
While executing the domain power-on,
070904-006
domain reset or DR, in case the XSCF reboot
occurred, the process may be aborted in some
or all of the XSB.
24
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1091 • April 2010
Workaround
None available at this time.
None available at this time.
From the Menu, select the Domain
Configuration page again.
Do not attempt to use write-protected USB
devices for collecting snapshot.
No workaround is available. This is expected
behavior of the sendbreak(8) operation.
Check the stratum value of the NTP server.
The stratum value of XSCF is "5." The NTP
server which the XSCF refers to must be a
server on which the stratum value is smaller
than 5. When you changed the NTP server to
refer to, reboot the XSCF.
When the stratum value has been set correctly
and the time can't be synchronized, use the
showntp(8) command to check the jitter value
to be displayed.
If this value is large, please reboot the XSCF.
Execute the domain reset one more time, or
power off the domain and then power on
again.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m5000

Table of Contents