Clearances To Combustibles - Quadra-Fire 2100 Millennium Owner's Manual

Advanced combustion technology (act) wood stove
Hide thumbs Also See for 2100 Millennium:
Table of Contents

Advertisement

R
CLEARANCES TO COMBUSTIBLES (UL AND ULC)
BACKWALL / SIDEWALL
A
B
C
D
CORNER INSTALLATION
E
F
E
F
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
INSTALLATION: Full Vertical OR Horizontal with Minimum 2 Foot Vertical Off Stove Top
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: 90° Elbow Off Top of Stove Through Backwall
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: ALCOVE
103 HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark
arrestor). Maximum depth of alcove shall be no more than 48"(1220mm) with a minimum height of 43" (1092mm) to top
of unit, and the referenced clearances.
DOUBLE WALL PIPE
* NPFA MINIMUM CLEARANCE - NOT TESTED
** SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
Page 6
2100 ACT Millennium Wood Stove
90° OFF TOP
UP & OUT CEILING
CLEARANCE
STOVE TO CEILING
CLEARANCE
A
B
C
16 (406) 13.5 (343) 19 (483) 11.5 (292) 9.5 (241) 17(432)
9 (229)
6 (152)
19 (483)
16 (406) 13.5 (343) 19 (483) 11.5 (292)
9 (228)
6 (152)
19 (483) 11 (279)
Six inch (6") (152mm) diameter listed double wall air insulated connector pipe with UL
11.5 (292) 9.5 (241)
22 (559)
ALCOVE SIDE VIEW
*
H
G
ALCOVE TOP VIEW
D
E
F
11 (279)
8 (203)
16 (406) 43 (1092)
9.5 (241) 17 (432) 43 (1092)
8 (203)
16 (406) 43 (1092)
14 (356)
N/A
N/A
250-6931C November 3, 2004
G
A
B
C
D
G
H
43 (1092) 18 (457)*
5 (127)
18 (457)*
5 (127)
43 (1092)
**

Advertisement