Quadra-Fire 21M-ACC Owner's Manual

Quadra-Fire 21M-ACC Owner's Manual

2100 millennium wood stove automatic combustion control (acc) installation and operation
Hide thumbs Also See for 21M-ACC:
Table of Contents

Advertisement

Important operating
a n d m a i n t e n a n c e
instructions included.
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate
poisonous gases (i.e. carbon monoxide).
Installation and service of this appliance should
be performed by qualifi ed personnel. Hearth &
Home Technologies recommends NFI certifi ed
professionals, or technicians supervised by an
NFI certifi ed professional.
www.quadrafi re.com
2100 MILLENNIUM WOOD STOVE
Automatic Combustion Control (ACC)
Owner's Manual
Installation and Operation
21M-ACC
DO NOT DISCARD THIS MANUAL
• Read, understand and
follow these instructions
for safe installation and
operation.
WARNING
Model:
NOTICE
• Leave this manual with
party responsible for
use and operation.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other
fl ammable materials away.
To obtain a French translation of this manual, please
contact your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel,
s'il vous plaît contacter votre revendeur ou visitez
www.quadrafi re.com
7039-131M
Tested and
Portland
O-T L
Oregon USA
Listed by
C
US
OMNI-Test Laboratories, Inc.
WARNING
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
NOTE
October 13, 2015

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 21M-ACC

  • Page 1 Portland O-T L Oregon USA Listed by Owner’s Manual OMNI-Test Laboratories, Inc. Installation and Operation Model: 21M-ACC NOTICE DO NOT DISCARD THIS MANUAL • • Read, understand and • Leave this manual with Important operating follow these instructions party responsible for...
  • Page 2 Hearth & Home Technologies welcomes you to our tradi- our stoves, inserts and fi replaces. And yet we are old-fash- tion of excellence! In choosing a Quadra-Fire appliance, ioned when it comes to craftsmanship. Each unit is meticu- you have our assurance of commitment to quality, durabil- lously fabricated and surfaces are hand-fi...
  • Page 3: Table Of Contents

    2100 Millennium Wood Stove (ACC) Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •...
  • Page 4: Section 1: Listing And Code Approvals

    Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualifi ed Quadra-Fire is a registered trademark of Hearth & Home installer, service agency or your dealer. Technologies. NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifi...
  • Page 5: Section 2: Getting Started

    2100 Millennium Wood Stove (ACC) Getting Started A. Design, Installation & Location Consider ations B. Fire Safety Consideration must be given to: To provide reasonable fi re safety, the following should be • Safety given serious consideration: • Convenience Install at least one smoke detector on each fl oor of •...
  • Page 6: Negative Pressure

    2100 Millennium Wood Stove (ACC) C. Negative Pressure To minimize the affects of negative air pressure the following Draft is the pressure difference needed to vent appliances must be considered: successfully. Considerations for successful draft include: • Install the outside air kit. Install the intake on the •...
  • Page 7: Flue Draft Considerations

    2100 Millennium Wood Stove (ACC) F. Tools And Supplies Needed D. Flue Draft Considerations Location of the appliance and chimney will affect perfor- Before beginning the installation be sure that the following mance. As shown in Figure 6.1 on page 6 the chimney tools and building supplies are available.
  • Page 8: Typical Stove System

    2100 Millennium Wood Stove (ACC) H. Typical Stove Systems Stove system with masonry chimney consists of: • Stove • Chimney Connector (stove pipe) • Thimble • Masonry Chimney • Hearth Pad Floor Protection Figure 8.1 Masonry Chimney Stove system with prefabricated metal chimney consists of: Listed Termination Cap Storm Collar...
  • Page 9: Appliance Dimensions

    2100 Millennium Wood Stove (ACC) Dimensions and Clearances A. Appliance Dimensions 23-3/8 in. (594mm) 8-5/8 in. 11-11/16 in. NOTE: Flue Collar size is 6 inch 219mm (297mm) (152mm) diameter (ID) 9-1/4 in. (235mm) 12-3/4 in. 13-1/2 in. (342mm) (324mm) 17 in. (432mm) 27-15/16 in.
  • Page 10: Clearances To Combustibles

    2100 Millennium Wood Stove (ACC) B. Clearances to Combustibles (UL and ULC) NOTE: A, C and F measurements are to center of fl ue INSTALLATION: Full Vertical SINGLE WALL PIPE - A, B, C and D dimensions are based off of standard 18” stove pipe clearances to combustibles or unit certifi ed clerances, which- ever is greater SINGLE WALL PIPE 18 [457]...
  • Page 11: Section 4: Installation Consideration A. Hearth Requirements

    2100 Millennium Wood Stove (ACC) Installation In Canada, similar fl oor protection must be provided 18 A. Hearth Protection Requirements inches (457mm) in front and 8 inches (203mm) from the FLOOR PROTECTION: Floor protector must be non-com- sides and rear of the stove. *See exception. bustible material, extending beneath heater and to the front, *EXCEPTION: Non-combustible fl...
  • Page 12: Outside Air

    2100 Millennium Wood Stove (ACC) B. Outside Air Kit Installation WARNING A source of air (oxygen) is necessary in order for combus- Fire Risk. tion to take place. Whatever combustion air is consumed by the fi re must be replaced. Air is replaced via air leakage Asphyxiation Risk.
  • Page 13: Blower Installation

    2100 Millennium Wood Stove (ACC) C. Blower (Optional) CAUTION 1. Remove the 3 bolts (1/4”-20 Phillips head) on the outer skin at the bottom rear of appliance. Shock Risk. 2. Align holes in mounting fl ange of blower with bolt holes in •...
  • Page 14: Section 5: Chimney Requirements

    2100 Millennium Wood Stove (ACC) Chimney Requirements A. Venting Components B. Chimney Systems Chimney Connector: Prefabricated Metal Chimney It is also known as fl ue pipe or stove pipe. The chimney • Must be minimum 6 inch (152mm) diameter (ID) high connector joins the stove to the chimney.
  • Page 15 2100 Millennium Wood Stove (ACC) Thimble Site constructed for masonry chimney installation: ceiling Components 13.5” below ceiling to top of opening • A minimum length of 12 inches [305mm] (longer for Wall or top of opening is a min.of thicker walls) of solid insulated factory-built chimney 4.5”...
  • Page 16: Installing Chimney Components

    2100 Millennium Wood Stove (ACC) Solid Pack Chimney with Metal Supports as a C. Installing Chimney Components Thimble (Cont’d) Chimney Connector Single wall connector or stove pipe. Min. Chimney Clearance to This must be at least 24 gauge mild steel or 26 gauge blue Wall Spacer and Min.
  • Page 17: Chimney Termination Requirements

    2100 Millennium Wood Stove (ACC) D. Chimney Termination Requirements NOTE: Follow manufacturer’s instructions for clearance, securing • Chimney performance may vary. fl ashing and terminating the chimney. • Trees, buildings, roof lines and wind conditions affect performance. • Must have an approved and listed cap •...
  • Page 18: Section 6: Mobile Home

    2100 Millennium Wood Stove (ACC) Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part OAK-ACC and (depending on fl oor installation, Part SRV7033-041) for installation in a mobile home. Snap Disc 1. An outside air inlet must be provided for combustion See page 12 for installation information.
  • Page 19: Section 7: Appliance Set-Up

    2100 Millennium Wood Stove (ACC) Appliance Set-Up B. Adjusting The Blower Speed Control A. Door Handle Assembly The blower speed control for this unit is adjusted at the factory, 1. Install washer on door handle shaft. and normally does not require further adjustment. 2.
  • Page 20: Section 8: Operating Instructions

    Much of the blame for poor air quality has been • Metal warping placed on the burning of wood for home heating. In order to improve the situation, we at Quadra-Fire have developed • Chimney fi re cleaner-burning woodstoves that surpass the requirements 2.
  • Page 21: Automatic Combustion Control (Acc)

    2100 Millennium Wood Stove (ACC) 2. Second Stage The second function of the Start-Up Air Control is operation The next stage of burning, the secondary stage, is the period of the rear air system. The rear air is used primarily during when the wood gives off fl...
  • Page 22: Burn Rates & Operating Effi Ciency

    2100 Millennium Wood Stove (ACC) 2. Burn Rate Air Control This air supply enters at the upper front of the fi rebox, near the Start-Up Air Control all the way back until it stops top of the glass door. This preheated air supplies the neces- (HI marker) and then pull forward until it stops.
  • Page 23: Building A Fire

    2100 Millennium Wood Stove (ACC) Operate appliance on High Burn 15 minutes a NOTE: Baffle Board even with front day to help keep fl ue/chimney clean. tube & resting on all tubes Burn Rate G. Building A Fire Air Control Before lighting your fi...
  • Page 24: Correct Baffl E & Blanket Placement

    2100 Millennium Wood Stove (ACC) H. Correct Baffl e & Blanket Placement INCORRECT POSITIONS WARNING Fire Risk Firebox damage due to improper baffl e place- ment is not covered by warranty. Operate the wood burning appliance with the baffl e in the correct position only.
  • Page 25: Blower Operating Instructions

    2100 Millennium Wood Stove (ACC) J. Opacity (Smoke) I. Blower Operating Instructions NOTE: If your Quadra-Fire wood stove is equipped with an This is the measure of how cleanly your appliance is burn- optional blower, you should follow these guidelines: ing.
  • Page 26: Frequently Asked Questions

    2100 Millennium Wood Stove (ACC) K. Frequently Asked Questions ISSUES SOLUTIONS Odor from appliance When fi rst operated, this appliance may release an odor for the fi rst several hours. This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Metallic noise Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct.
  • Page 27: Maintaining & Servicing Appliance

    2100 Millennium Wood Stove (ACC) Maintaining & Servicing Your Appliance A. Quick Reference Maintenance Guide BAFFLE & BLANKET PLACEMENT INSPECT FIREBRICKS & ASH GRATE (AFTER EACH CLEANING) Back of Firebox Ceramic Blanket Baffle Retainer Bracket Baffle Board Step Top Models Only Baffl...
  • Page 28: General Maintenance & Cleaning

    2100 Millennium Wood Stove (ACC) B. General Maintenance 2. Disposal of Ashes 1. Creosote (Chimney) Cleaning • Frequency: When ash is within 1-3/4 in. (44mm) of firebox lip • Frequency: Every 2 months during heating season or • By: Homeowner as recommended by a certifi...
  • Page 29: Glass Replacement

    DO NOT OVERTIGHTEN. Replace the door on the appliance. Quadra-Fire stoves are equipped with ceramic super heat- resistant glass, which can only be broken by impact or misuse. Do not slam stove door or impact the glass. When closing door, make sure that logs do not protrude against the glass.
  • Page 30: Firebrick Replacement

    2100 Millennium Wood Stove (ACC) D. Firebrick Replacement Replace the fi rebrick if they become crumbly and/or if there is a 1/4 inch (6.35mm) gap between the bricks. Inspect the fi rebrick after each ash removal. The fi rebox is lined with high quality fi rebrick, which has exceptional insulating properties.
  • Page 31: Baffl E Removal

    2100 Millennium Wood Stove (ACC) F. Snap Disc Replacement E. Baffl e Removal 1. Locate the snap disc bracket assembly at the bottom left 1. Remove all ash from the fi rebox, and extinguish all hot rear corner of the stove. Figure 31. 3. embers before disposal into a metal container.
  • Page 32: Tube Channel Replacement

    2100 Millennium Wood Stove (ACC) G. Tube Channel Assembly Replacement NOTE: Service Space In order to replace the tube channel assembly a clear- Removing Tube Channel Assembly ance of 17 inches (432mm) is required on the right side 1. Remove the right side shield by removing 2 screws in the of stove in order to remove the tubes with the stove in back using a Phillips head screw driver.
  • Page 33: Section 10: Troubleshooting

    2100 Millennium Wood Stove (ACC) With proper installation, operation, and maintenance your wood stove will provide years of trouble-free service. If you do experience a prob- lem, this troubleshooting guide will assist a qualifi ed service person in Troubleshooting the diagnosis of a problem and the corrective action to be taken. Start Fire Problems Possible Cause Solution...
  • Page 34: Exploded Drawings & Service Parts List

    2100 Millennium Wood Stove (ACC) Reference Materials A. Exploded Drawings & Service Parts List Part number list on following pages. 09/15 Figure 34.1 Page 34 7039-131M October 13, 2015...
  • Page 35: Service Parts

    2100 Millennium Wood Stove (ACC) 21M-ACC Service Parts Beginning Manufacturing Date: July 2007 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 36 2100 Millennium Wood Stove (ACC) 21M-ACC Service Parts Beginning Manufacturing Date: July 2007 Ending Manufacturing Date: Active # 16 Burn Rate Control Assembly #17 Door Assembly #18 Baf e Protection Channel Side view 16.10 16.1 16.9 Front, looking into unit 17.1...
  • Page 37 DESCRIPTION COMMENTS PART NUMBER Component Pack (Includes Gold Spring Handles (1) 1/2" For Black & Gold 436-5350 & (2) 1/4", (2) Gold Hinge Pins, Quadra-Fire Logo Doors Gasket, Glass Tape 5 FT 832-0460 Rope, Door, 3/4” X 84” 7 Ft...
  • Page 38: Warranty Policy

    2100 Millennium Wood Stove (ACC) B. Warranty Policy Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized deale WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownersh of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 39 2100 Millennium Wood Stove (ACC) WARRANTY CONDITIONS: ‡ 7KLV ZDUUDQW\ RQO\ FRYHUV ++7 DSSOLDQFHV WKDW DUH SXUFKDVHG WKURXJK DQ ++7 DXWKRUL]HG GHDOHU RU GLVWULEXWRU $ OLVW RI ++7 DXWKRUL]HG GHDOHUV LV DYDLODEOH RQ WKH ++7 EUDQGHG ZHEVLWHV ‡ 7KLV ZDUUDQW\ LV RQO\ YDOLG ZKLOH WKH ++7 DSSOLDQFH UHPDLQV DW WKH VLWH RI RULJLQDO LQVWDOODWLRQ ‡...
  • Page 40: Contact Information

    Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, visit our web site at www.quadrafi re.com NOTICE DO NOT DISCARD THIS MANUAL •...

Table of Contents