Clearances To Combustibles - Quadra-Fire 27I-ACC Installation Manual

2700 insert wood insert automatic combustion control (acc)
Hide thumbs Also See for 27I-ACC:
Table of Contents

Advertisement

B. Clearances to Combustibles
28 1/2
724mm
USA 16-3/4
CANADA
20-3/4 (527mm)
If trim measurement is over 3/4 in (19mm)
NOTE:
in depth use mantle or side clearances
to combustibles.
43-1/2
1105mm
See next page for thermal protection
In Canada a full length 6 inch (152mm) S635 flue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter flue liner is required as per UL 1482.
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
November 22, 2019
TOP TRIM
21-3/4
552mm
HEARTH
EXTENSION
12in max
MANTEL
USA 17
CANADA 19 (483mm)
HEARTH EXTENSION
requirements
United States and Canada (UL and ULC)
36-1/16
916mm
Minimum Opening Dimensions
A
Height
B
Front Width
C
Back Width
D
Depth
NOTE: Minimum opening dimensions include a 1/4"
(6mm) clearance around unit.
NOTE: Clearances may only be reduced by
means approved by the regulatory authority
having jurisdiction
7046-192I
2700 Insert ACC
A
D
C
B
Inches
19-1/2
33
20-3/8
17-7/8
Millimeters
495
832
511
454
9