Clearances To Combustibles - Quadra-Fire 4300 Series Installation Manual

Automatic combustion control (acc)
Table of Contents

Advertisement

4300 Wood Appliance Series ACC
C. Clearances to Combustibles
SINGLE WALL PIPE
MILLENNIUM
STEP TOP
DOUBLE WALL PIPE
MILLENNIUM
STEP TOP
DOUBLE WALL PIPE
MILLENNIUM
STEP TOP
DOUBLE WALL PIPE
MILLENNIUM
STEP TOP
For alcove only: Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry
chimney. Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced alcove clearances. Canada must comply with
BACKWALL / SIDEWALL
A
B
C
D
CORNER INSTALLATION
E
F
E
F
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
14
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters)
Note: A, C, and F Dimensions are to the center of the flue collar
4300 WOOD APPLIANCE
INSTALLATION: FULL VERTICAL
A
B
18-1/2 (470)
11-3/4 (298)
27-1/2 (699)
18-1/2 (470)
11-3/4 (298)
27-1/2 (699)
12 (305)
5-1/4 (133)
27-1/2 (699)
10-1/2 (267)
3-3/4 (95)
25 (635)
INSTALLATION: 90 DEGREE ELBOW OFF TOP OF APPLIANCE THROUGH BACKWALL
11-1/2 (292)
6 (152)
27-1/2 (699)
10-1/2 (267)
4 (102)
22 (559)
INSTALLATION: ALCOVE
16 (406)
10 (254)
27 (686)
10-1/2 (267)
3-3/4 (95)
25 (635)
CAN/ULC-S269 M87 for the 650° factory built chimney.
* FOLLOW PIPE MANUFACTURES CLEARANCES AS REQUIRED
ALCOVE SIDE VIEW
ALCOVE TOP VIEW
7037-172G
C
D
E
14-1/2 (368)
10 (254)
14-1/2 (368)
2 (51)
14-1/2 (368)
10 (254)
11-3/4 (298)
2 (51)
15 (381)
10 (254)
9 (229)
2 (51)
14-1/2 (368)
N/A
11-3/4 (298)
N/A
G
A
C
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 19 inches (483mm) is required on the right side of
appliance in order to remove the tubes with the appliance
in place.
If space is not available, the appliance will have to be
disconnected from the chimney to proceed with the tube
replacement.
F
G
20-1/2 (521)
53-1/2 (1359)
15 (381)
49-1/2 (1283)
20-1/2 (521)
53-1/2 (1359)
15 (381)
49-1/2 (1283)
20-1/2 (521)
53-1/2 (1359)
15 (381)
49-1/2 (1283)
N/A
53-1/2 (1359)
N/A
49-1/2 (1283)
G
APPLIANCE
TO CEILING
CLEARANCE
* If H = N/A, follow Pipe
Manufacturer's clearances
August 13, 2018