Clearances To Combustibles - Quadra-Fire 43ST-ACC-AU Installation Manual

Hide thumbs Also See for 43ST-ACC-AU:
Table of Contents

Advertisement

D. Clearances to Combustibles
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in Millimeters Note: A, C, and F
Dimensions are to the center of the flue collar 4300 Stop Top Wood Appliance
A
Australian
295
Default Flue Kit
C
E
D
Figure 11.1
L
L
Figure 11.3
11
INSTALLATION
B
C
D
150
705
375
H
G
K
K
F
F
J
J
G
G
E
F
G
70
150
800
Figure 11.2
NOTE: This appliance is also tested and approved with
a VisionLINE insulated flue kit with the same clearances.
NOTE: Service Space
In order to replace the tube channel assembly a clearance
of 483mm is required on the right side of appliance in
order to remove the tubes with the appliance in place.
If space is not available, the appliance will have to be
disconnected from the chimney to proceed with the
tube replacement.
7037-806A
H
I
J
1130
400
796
A
I
K
L
1376
1536
B
05/21