4. Outdoor fan control
SM160
W1
High
250
Low
1) Cooling fan control
Q
The outdoor fan is controlled by TE, TD, and TO sensors and also revolution frequency of the opera-
tion. The outdoor is controlled by every 1 tap of DC fan control (15 taps).
R
Only during 60 seconds after the operation has started, the fan is fixed with the maximum fan tap
which corresponds to the zone in the following table.
After then the fan is controlled by TE sensor temperature.
S
Considering a case that TE sensor has come out of the holder, the fan is controlled so that revolution
frequency of the fan increases regardless of TE if temperature of TD sensor has risen.
SM160
TE [˚C]
a
b
(The operation frequency differs according to the model type.)
Temp. range
29°C < TO
15 < TO < 29°C
5 < TO < 15°C
0 < TO < 5°C
–5 < TO < 0°C
TO < –5°C
TO error
Allocations of fan tap revolutions [rpm]
W2
W3
W4
W5
260
260
320
380
240
300
400
a
b
37
34
+1 tap/20 seconds
rpm hold
–1 tap/20 seconds
Below 30Hz
Min.
Max.
W5
WA
W3
W7
W2
W5
W1
W3
W1
W2
OFF
OFF
W1
WE
W6
W7
W8
W9
480
500
530
610
500
520
550
630
TD [˚C]
85
80
75
65
Above 30 Hz below 45 Hz
Min.
W7
W5
W4
W3
W2
OFF
W1
– 65 –
WA
WB
WC
WD
640
660
720
720
660
700
740
740
Operation with WE
Operation with
maximum tap in
each zone
Usual fan control
Above 45 Hz
Max.
Min.
WC
W9
W9
W7
W7
W6
W5
W4
W4
W3
W3
OFF
WE
W1
WE
WF
720
780
740
820
Max.
WE
WB
W9
W7
W5
W3
WE