Step 6: (Electric Dryer Only) Connect
Electrical Plug
Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz,
3 or 4 wire electrical supply. Refer to serial plate for
specific electrical requirements.
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
WARNING
To reduce the risk of fire, electric shock,
serious injury or death, all wiring and
grounding MUST conform with the latest
edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local
regulations as might apply. It is the
customer's responsibility to have the wiring
and fuses installed by a qualified electrician
to make sure adequate electrical power is
available to the dryer.
802714R5
W521
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Grounding Information

• This dryer must be connected to a grounded
metal, permanent wiring system; or an
equipment-grounding conductor must be run
with the circuit conductors and connected to the
equipment-grounding terminal or lead on the
dryer.
• The dryer has its own terminal block that must be
connected to a separate branch, 60 Hertz, single
phase circuit, AC (alternating current) circuit,
fused at 30 Amperes (the circuit must be fused
on both sides of the line). Electrical service for
the dryer should be of maximum rated voltage
(208 or 240 volt, depending on heating
element) listed on the nameplate. Do not
connect dryer to 110, 115, or 120 volt circuit.
• Heating elements are available for field
installation in dryers which are to be connected to
electrical service of different voltage than that
listed on nameplate, such as 208 Volt.
NOTE: Branch circuit wire size requirements to
laundry room outlet are shown in Table 3.
Wire Length
Less than 15 ft. (4.5 m)
Longer than 15 ft. (4.5 m)
• The power cord connection between wall
receptacle and dryer terminal block IS NOT
supplied with dryer. Type of power cord and
gauge of wire must conform to local codes.
Dryer
Listed No. 10 AWG
Copper wire only
Listed No. 8 AWG
Copper wire only
Table 3