Resetting A Forticarrier-5001A Board - Fortinet FortiCarrier-5001A-DW Manual

Table of Contents

Advertisement

Resetting a FortiCarrier-5001A board

Resetting a FortiCarrier-5001A board
20
7
Turn both handles to their fully-closed positions.
Alignment Pin
Close
8
Carefully slide the board completely out of the slot.
9
Re-attach the protective metal frame before shipping or storing the
FortiCarrier-5001A board.
By default you must eject the FortiCarrier-5001A board from the chassis slot to
cycle the power and reset the board. See
on page 18
for information about how to eject a FortiCarrier-5001A board from a
chassis.
The FortiCarrier-5001A includes a microswitch that can be used to power the
board off and on by opening and closing the right (bottom) handle. By opening and
closing the right handle you can reset the FortiCarrier-5001A board without
ejecting the board from the chassis. Before you can do this you must enable the
microswitch using the following FortiCarrier-5001A CLI command:
config system global
set microswitch {enable | disable}
end
Caution: The right (bottom) handle (and the microswitch) must be closed before you enter
this command.
Once you enter this command, you can use the following procedure to reset a
FortiCarrier-5001A board without ejecting it from the chassis.
To reset a FortiCarrier-5001A board without removing the board from the
chassis
You do not have to loosen the retention screws or adjust the position of the
FortiCarrier-5001A board to use this procedure.
To complete this procedure, you need:
An ATCA chassis with a FortiCarrier-5001A board installed
An electrostatic discharge (ESD) preventive wrist strap with connection cord
Caution: FortiCarrier-5001A boards must be protected from static discharge and physical
shock. Only handle or work with FortiCarrier-5001A boards at a static-free workstation.
Always wear a grounded electrostatic discharge (ESD) preventive wrist strap when
handling FortiCarrier-5001A boards.
Handle
Fully Closed
and Locked
"Removing a FortiCarrier-5001A board"
FortiCarrier-5001A Security System Guide
Hardware installation
Alignment Pin
Handle
01-400-91945 -20090223