Main Functions
Time chart for
Approx. 1min. after HUMID HEAT operation start up, it repeats humidifying and drying
alternately (to protect condensation for inside the hose).
humidifying
operation control
When a room is spacious such as loft style or partitioned by accordion style curtain, the
ventilation volume is large and may not sometimes reach the set humidity.
12
ON
HUMID HEAT
OFF
operation
ON
Humidifying fan
and damper
OFF
ON
Hygroscopic
OFF
fan
ON
Dry mode
Heater
OFF
ON
Rotor
OFF
. Humidifying time
Approx. 70min.
. Drying time
Approx. 2~10min.
'. Drying time
Approx. 2~10min.
Time chart for HUMID HEAT operation on trial mode
HUMID HEAT operation on trial mode works in the same sequence as HUMID HEAT
operation, but about 30 min. later it automatically stops.
Remark
Approx. 1min
b'
a
b
15 sec.
Decide time according to the outdoor temperature
and hose length set by remote controller.
Decide time according to the hose length set by
remote controller.
Approx. 3min
a
b
a
b'
15 sec.
Function and Control