1.
Verify water level is 1" below lowest pillow. Add water if necessary.
2.
Check for clogged or dirty filter cartridge (sec. 12.1, page
3.
Purge "air lock" from circulation pump intake by removing filter
cartridge. Hold your garden hose over the filter cartridge wall fitting
while using a rag as a seal around hose end. Ask a helper to turn
on water for 30 seconds, then turn off. Reinstall filter cartridge and
check spa (sec. 12.1, page 32).
4.
If the circulation pump is not running, turn power off at the main
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
5.
If problem persists, contact your authorized Jacuzzi dealer.
14.8

panel Displays oH

warnInG:
!
Causing severe inJury, burns, or welts.
Water temperature is above acceptable limits. Do noT
enTer spa! Water temperature has reached 112˚F
(44˚C) and the low speed jets pump 1 and optional
circulation pump (when equipped) has activated to circulate water
through heater. Contact your authorized Jacuzzi dealer or qualified
service technician.
14.9

panel Displays (- - -)

warnInG:
!
Causing severe inJury, burns, or welts.
Water temperature is above acceptable limits. Do noT
enTer spa! The safety "Watchdog" software has been
triggered and the spa is deactivated. A problem has been
detected which could cause damage to the spa or its
components. Contact your authorized Jacuzzi dealer or qualified service
technician.