14.6

panel Flashes Fl1 or Fl2

A flashing "FL1" display means the flow switch is
malfunctioning open, the filter cartridge is excessively
dirty or an "air lock" condition has occurred at the
circulation pump intake. A flashing "FL2" display means
the flow switch is malfunctioning closed. In either case,
the spa heater will deactivate and jets pump #1 may
also deactivate. To correct condition perform the following:
1. Verify water level is above all jets but below lowest pillow. Add water
if necessary.
2. Check for clogged or dirty filter cartridge (sec. 12.1, page 30).
3. Purge "air lock" from circulation pump intake by removing filter
cartridge. Hold your garden hose over the filter cartridge wall fitting
while using a rag as a seal around hose end. Ask a helper to turn
on water for 30 seconds, then turn off. Reinstall filter cartridge and
check spa (sec. 12.1, page 30).
4. If the circulation pump is not running, turn power off at the main
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
5. If problem persists, contact your authorized Jacuzzi dealer.
14.7

panel Displays oH

warnInG:
!
Causing severe inJury, burns, or welts.
Water temperature is above acceptable limits. Do noT enTer spa!
Water temperature has reached 112 ˚F (44 ˚C) and the low
speed jets pump 1 and optional circulation pump (when
equipped) has activated to circulate water through heater.
Contact your authorized Jacuzzi dealer or qualified service technician.
To correct condition:
Remove the spa's cover and allow your spa to cool down.
Program the filter settings for Economy Mode (page
temperature setting to cancel Summer Logic condition (page 38).
If the condition persists, contact your authorized Jacuzzi dealer.
14.8

panel Displays (- - -)

warnInG:
!
Causing severe inJury, burns, or welts.
Water temperature is above acceptable limits. Do noT
enTer spa! The safety "Watchdog" software has been
triggered and the spa is deactivated. A problem has been
detected which could cause damage to the spa or its components.
Contact your authorized Jacuzzi dealer or qualified service technician.
rIsK oF HYperTHermIa (over-HeaTInG)