Napoleon GVF42N Installation And Operation Instructions Manual page 12

Unvented millivolt system, gas fireplace
Table of Contents

Advertisement

12
OPTIONAL BLOWER INSTALLATION
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be electrically connected and grounded in accord-
ance with local codes. In the absence of local codes, use the
current ANSI/NFPA 70
NATIONAL ELECTRICAL CODE
FIGURE 19
The three slots on the
blower
mounting
bracket allow ease of
adjustment
when
attaching the blower. For
a quiet running blower,
do not allow the assem-
bly to sit on the firebox
base.
If optional blower kit is to be installed, remove thermodisc
from the bracket supplied in the kit and disgard the bracket.
Install thermodisc in the bracket supplied with the fire-
place. It is recommended to attach the wires to the disc
and install the bracket before installing the blower. Attach
the black and white wires to the disc, then secure the
bracket to the stud at the bottom left on the unit using the
lock washer and wing nut. Ensure that the thermodisc
touches the firebox wall.
Slide the vibration reducing pad (A) into the clip (C) and up
against the threaded stud (B) at the other end. The blower
must be able to be positioned entirely onto the pad.
Tilt the blower onto its side. Slide it past the controls and
into the clip (C). Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower
does not touch the fireplace base or the firebox.
W415-0379 / B / 08.03.05
.
If the fireplace was
not
previously
equipped
with
a
route
a
blower:
grounded 2-wire, 60hz
power cable to the
junction box. At this
point, it must be strain
relieved and insulated.
FIGURE 20
B
A
FIGURE 22
Attach the connectors from the
black and red wires to the
blower.
Attach and secure the variable
speed switch using the nut pro-
vided. Plug the harness cord into
the receptacle.
The wire harness provided in this kit is a universal har-
ness. When installed, ensure that any excess wire is
contained, preventing it from making contact with mov-
ing or hot objects.
Because the blower is thermally activated, when turned
on, it will automatically start approximately 10 minutes
after lighting the fireplace and will run for approximately
30-45 after the fireplace has been turned off. Use of the
fan increases the output of heat.
Drywall dust will penetrate into the blower bearings caus-
ing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or
its compartment. Any damage resulting from this condi-
tion is not covered by the warranty policy.
FIGURES 21
C
FIGURE 23