Venting System Components - Vermont Castings Intrepid INDVRCB Homeowner's Installation And Operating Manual

Direct vent, rear vent gas heater
Hide thumbs Also See for Intrepid INDVRCB:
Table of Contents

Advertisement

Intrepid® Direct Vent - Rear Vent Gas Heater
Fig. 16 Correct position of fan skirt installation.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat
ST240
wire harnesses together to the tubing under the
FDV attach fan
bottom of the unit.
12/13/99 djt
Approved Vent System Components
The Intrepid Heater must be vented to the outdoors
through an adjacent exterior wall or through the roof.
The venting system must be comprised of the appropri-
ate listed venting components specified on this page.
These parts are available from DuraVent Corporation.
See Figure 4 for dimensions relevant to the standard
minimum-vent kits.
Simpson DuraVent Components
www.duravent.com
Phone: 1-800-835-4429, Fax: 1-707-446-4740
Minimum Horizontal Vent Kit
Venting Component required for:
Basic Straight Through-the-Wall Installation
Horizontal Termination Cap
MHSC Zero Clearance Sleeve (included)
Firestop
Wall Thimble Cover
24" Straight (Maximum length)
Hardware Package (2 req'd)
NOTE: Simpson DuraVent Wall Thimble, 46DVA-WT
is not approved for use with this appliance except in
noncombustible masonry walls.
For corner installation add:
45° Elbow, Blk.
Venting Components
90° Elbow, Blk.
45° Elbow, Blk.
6" Straight, Blk.
9" Straight, Blk.
8¹⁄₂" Pipe Extension, Blk
16" Pipe Extension, Blk
12" Straight
14
KT902
Fig. 17 Attach rheostat to bracket.

Venting System Components

24" Straight
36" Straight
48" Straight
Square Horizontal Termination Cap
Sconce Horizontal Termination Cap
Round Horizontal Termination Cap
Wall Plate
Vinyl Siding Standoff
Snorkel Termination - 14"
Snorkel Termination - 36"
Wall Strap
Cathedral Ceiling Support Box
46DVA-KHC
Storm Collar
Firestop Spacer
Flashing 0/12 - 6/12
46DVA-HRC
Flashing 6/12 - 12/12
54623
Wall Thimble
46DVA-WFS
Wall Thimble Cover (Brass)
46DVA-DC
Wall Firestop
46DVA24B
Attic Insulation Shield
56167
Steel Chimney Conversion Kit
Kit A (6B⁄," - 8B⁄,")
Kit B (6B⁄," - 10¹⁄₂")
Kit C (6B⁄," - 13")
Masonry Chimney Conversion Kit
Vertical Termination Cap (High Wind)
46DVA-E45B
Vertical Termination Cap (Low Profile)
*Included in Minimum Horizontal Vent Kit 46DVA-KHC
46DVA-E90B*
46DVA-E45B
All DuraVent Straight vent pipe sections have a net
46DVA-06B*
length 1¹⁄₂" (37 mm) less than the nominal dimension;
46DVA-09B
i.e., a 6" (152 mm) Straight pipe section has an effec-
46DVA-08AB*
tive length of 4¹⁄₂" (115 mm).
46DVA-16AB
Refer to Simpson Duravent website for additional com-
46DVA-12
ponents. (www.duravent.com)
Retaining Nut
Rheostat Knob
ST347a
JUV
FK28
rheostat install
9/21/00
Rheostat
KT903
46DVA-24B*
46DVA-36B
46DVA-48
46DVA-HC
46DVA-HSC
46DVA-HRC
46DVA-DC*
46DVA-VSS
46DVA-SNK14
46DVA-SNK30
46DVA-WS
46DVA-CS
46DVA-SC
46DVA-FS
46DVA-F6
46DVA-F12
46DVA-WT*
3PVP-TKV
46DVA-WFS
46DVA-IS
46DVA-KCA
46DVA-KCB
46DVA-KCC
46DVA-KMC
46DVA-VCH
46DVA-VC
20012761

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents