Intrepid® Direct Vent - Rear Vent Gas Heater
Figure 16 - Correct position of fan skirt installation.
Attach the control knob to the rheostat shaft.
Use the wire tie to secure the fan and rheostat wire
ST240
harnesses together to the tubing under the bottom of
FDV attach fan
12/13/99 djt
the unit.
Approved Vent System Components
The Intrepid Heater must be vented to the outdoors
through an adjacent exterior wall or through the roof. The
venting system must be comprised of the appropriate listed
venting components specified on this page. These parts
are available from DuraVent Corporation.
See Figure 4 for dimensions relevant to the standard
minimum-vent kits.
DuraVent Components
www.duravent.com
Phone: 1-800-835-4429, Fax: 1-707-446-4740
Minimum Horizontal Vent Kit
Venting Component required for:
Basic Straight Through-the-Wall Installation
Horizontal Termination Cap
Vermont Castings Zero Clearance
Sleeve (included)
Firestop
Wall Thimble Cover
24" Straight (Maximum length)
Hardware Package (2 req'd)
NOTE: DuraVent Wall Thimble, 46DVA-WT is not
approved for use with this appliance except in
noncombustible masonry walls.
For corner installation add:
45° Elbow, Blk.
Venting Components
90° Elbow, Blk.
45° Elbow, Blk.
6" Straight, Blk.
9" Straight, Blk.
8
" Pipe Extension, Blk
1
2
16" Pipe Extension, Blk
12" Straight
24" Straight
36" Straight
48" Straight
3-90-20306761

Venting System Components

46DVA-KHC
46DVA-HRC
54623
46DVA-WFS
46DVA-DC
46DVA24B
56167
46DVA-E45B
46DVA-E90B*
46DVA-E45B
46DVA-06B*
46DVA-09B
46DVA-08AB*
46DVA-16AB
46DVA-12
46DVA-24B*
46DVA-36B
46DVA-48
Vermont Castings • Intrepid DV Owner's Manual_R3 • 12/16
Retaining Nut
Rheostat Knob
Figure 17 - Attach rheostat to bracket.
Square Horizontal Termination Cap
Sconce Horizontal Termination Cap
Round Horizontal Termination Cap
Wall Plate
Vinyl Siding Standoff
Snorkel Termination - 14"
Snorkel Termination - 36"
Wall Strap
Cathedral Ceiling Support Box
Storm Collar
Firestop Spacer
Flashing 0/12 - 6/12
Flashing 6/12 - 12/12
Wall Thimble
Wall Thimble Cover (Brass)
Wall Firestop
Attic Insulation Shield
Co-Linear Vent Adapter
Steel Chimney Conversion Kit
Kit A (6
" - 8
")
5
5
8
8
Kit B (6
" - 10
")
5
1
8
2
Kit C (6
" - 13")
5
8
Masonry Chimney Conversion Kit
Vertical Termination Cap (High Wind)
Vertical Termination Cap (Low Profile)
*Included in Minimum Horizontal Vent Kit
All DuraVent Straight vent pipe sections have a net length
1
" (37 mm) less than the nominal dimension; i.e., a 6"
1
2
(152 mm) Straight pipe section has an effective length of
4
" (115 mm).
1
2
Refer to the DuraVent website for additional components.
(www.duravent.com)
Rheostat
ST347a
JUV
FK28
rheostat install
9/21/00
46DVA-HC
46DVA-HSC
46DVA-HRC
46DVA-DC*
46DVA-VSS
46DVA-SNK14
46DVA-SNK30
46DVA-WS
46DVA-CS
46DVA-SC
46DVA-FS
46DVA-F6
46DVA-F12
46DVA-WT*
3PVP-TKV
46DVA-WFS
46DVA-IS
46DVA-GCL
46DVA-KCA
46DVA-KCB
46DVA-KCC
46DVA-KMC
46DVA-VCH
46DVA-VC
46DVA-KHC
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

IndvrbssbIndvrcbsbIndvrbmsb

Table of Contents