9.0 Configuration

This section describes how to reconfigure the input voltage of the PW5125 UPS:
Configuration Mode
When the UPS is in Configuration mode. the front panel LEDs represent the configuration options. The
control buttons (Configuration button, On button, Off button and Alarm Reset button) are used to modify the
UPS configuration. Figure 14 shows the indicators and Table 10 explains the corresponding options.
1.
Remove the front plastic cover - refer Page 18 for instructions. Press the Configuration mode
button until the green configuration LED is On. The indicators flash briefly and then display the
enabled option.
2.
Press the On button to scroll through the options. Each time you press the button, the UPS
beeps. The indicator for the selected option indicates the current setting; flashing represents a
selected but as yet disabled option.
3.
Press the Off button once to toggle the selected option ON (this will cause the flashing indicator to
go solid and the original selected option LED to go out.
4.
Press the Alarm Reset button until the green Configuration LED goes out.
The UPS exits the Configuration mode automatically after two (2) minutes
WA R N I N G
causing the green Configuration LED to go out.
Figure 14 Using the Configuration Mode
1.
Remove the front plastic cover -
refer Page 18 for instructions. Press
the Configuration mode button until
the green configuration LED is On.
2.
Press the On button to scroll to the
next option.
3.
Press the Off button to toggle the
option ON.
4.
Press the Alarm Reset button to
save the setting and exit
Configuration mode.