Changing the remote timeout

By default, the Mio R-4 will go to sleep at the same time as the selected display timeout if the device is
not already in its charging cradle. By disabling this default, the device remains connected to the rest of
the ZigBee network while the device is otherwise asleep, and allows a faster response when picked up
again. In this mode, the button backlight and the touchscreen turn themselves off after the Display
Timeout time is reached, but the remote remains online until after the set Sleep Timeout is reached. After
this point, the device will reconnect to the network, but this reconnection will be much faster than if the
device were shut off.
1. Select Remote & Display Settings from the Setup Page.
2. Under Display Timeout, use the Up/Down arrows to adjust the timeout period in five-second
increments, to a maximum of 30 seconds.
3. Under Sleep Timeout, use the Up/Down arrows to adjust the timeout period in regular increments, to
a maximum of 240 minutes.
The Sleep Timeout period increments are 0 (sleep timeout disabled, remote will stay
active until the battery charge runs low), 3, 5, 10, 15, 30, 60, 120, 180, and 240
minutes.
4. To disable the default setting and allow separate display and sleep timeouts, press the Sleep on
Display Timeout button. When Sleep on Display Timeout is engaged, the button is green (FIG. 7),
and the Sleep Timeout settings will be greyed out. Press the button again to re-enable the Sleep on
Display Timeout function..
FIG. 7
Sleep on Display Timeout - enabled
12
The highest port number specified in the project pages.
The highest address specified in the project pages.
The highest channel specified in the project pages.
The highest level specified in the project pages
The refresh rate, in screen lines, of the Setup page screen display.
The width (in pixels) of the Setup page screen display.
The height (in pixels) of the Setup page screen display.
The rate (in seconds) at which features on the screen will blink.
The code string chosen by the NetLinx administrator for the unit wake-up.
The code string chosen by the NetLinx administrator for the unit sleep mode.
The code string chosen by the NetLinx administrator for the unit startup.