Igniting the Burners

The hob is fitted with a flame failure
device. Flame failure devices operate
by shutting off the supply of gas to the
burner in the event that the flame is
extinguished accidentally.
To ignite the burners, follow these
instructions:
1. Lightly press the control knob down and turn the knob
anticlockwise to the maximum position. Firmly press and hold down
the control knob to begin the ignition process (a clicking sound
will be heard). Hold down the control knob for a few seconds after
ignition to allow the safety device to detect that the burner is lit.
2. Once the burner is lit, adjust the burner power to the required
position.
Please note:
The ignition device should not be operated for more than 15
seconds.
I f a burner does not ignite, or turns off accidentally, turn the
control knob to the 'off' position, and wait for one minute before
attempting to reignite the burner.
I f the burner does not ignite, repeat the ignition process with the
burner at the minimum position.