Holder Shaft Unit Removal - Epson Stylus C50 Service Manual

Color inkjet printer
Table of Contents

Advertisement

EPSON Stylus C50/C60/C61/C62

4.3.7 Holder shaft unit removal

1.
Remove the Upper housing from the printer. (Refer to Section 4.3.1)
2.
Remove the ASF unit from the printer (Refer to Section 4.3.5)
3.
Release the Head FFC from the Spacer FFC on the LD roller shaft holder.
LD roller shaft holder
Spacer FFC
Figure 4-31. Head FFC removal
4.
Disconnect the CR motor connector cable and the HP/PE Sensor cable from the
connectors (CN4, CN12) on the Main board.
5.
Release the CR motor connector cable from five hooks on the LD roller shaft
holder.
6.
Release the Change lever toward the backside of the printer by using the tweezers,
and move the CR unit to the leftmost side (far side).
7.
Push two hooks of the LD roller shaft holder, and pull the Holder shaft unit
upward slightly from the Main frame. (Step1, 2 in the Figure 4-32)
Disassembly and Assembly
The Head FFC for Stylus C60 is
wider than that for Stylus C50.
Connector
Disassembly
8.
Move the Pump unit to the right side slightly while holing the whole of the Holder
shaft unit, and pull the bottom of the Holder shaft unit toward the backside of the
printer. (Step 3 in the Figure 4-32)
Step2) Pull the Holder shaft unit upward
Step1) Push two hooks
Figure 4-32. LD roller shaft holder removal
9.
Remove the LD roller shaft along with the Clutch mechanism from the LD roller
shaft holder.
Clutch mechanism
Spur gear 35.2
LD roller shaft
Figure 4-33. LD roller with Clutch mechanism removal
Revision C
Holder shaft unit
Step3) Move the Pump unit
to the right side
LD roller shaft holder
LD roller
106