Temperature Meter

The temperature meter displays the temperature of the combustor, allowing the operator to monitor
combustor light-off. To obtain a suitable temperature meter, contact the manufacturer listed below:
1
Before installing the faceplate, route the thermocouple wire to the catalytic combustor (see the
illustration below). With the wire in place, the faceplate can be installed.
Run the wire through this
c
notch
NOTE: if the notch is not
present, file a notch in the
arched piece of metal)
Attach the molex connector from the wire to the
e
quick-connect on the temp meter. Route the
wire so it exits below the faceplate.
Travis Industries

Optional Equipment

Condar Company
P.O. Box 250
108 Mill Spring Road
Columbus, NC 28722-0250
(828) 894-8383
Model: 9-88
NOTE: If the connector is not present, connect the wires
to the two posts on the back of the temp meter. The
yellow inner wire goes to the positive (+) pole.
a
b
d
9 3 5 0 8 0 9 1
Remove this screw and pass the
soldered end of the included
thermocouple wire through the hole.
NOTE: if the hole is not present, drill a
1/8" diameter hole (drill frominside the
firebox).
5/16" Nutdriver
Insert the soldered end of the wire into the
catalytic combustor approximately 1/2"
Route the wire along the outside of the
firebox assembly, behind the location
where the face attaches (either side).
Tuck excess wire to the side so it does
not contact the firebox.
Temp Meter