total-time specifies the total number of seconds to play the ring tone before it times out
Example 1: n=Classic-1;w=3;c=1
Example 2: n=Simple-1;w=2;c=1
Example 3: (TBD)
LedScript – A script that describes the color and blinking pattern of a Line Key LED. Each script contains
a number of fields separated by a semicolon(;). White spaces are ignored. Each field has the syntax
<field-name> = <field-value>. The allowed field-name and corresponding field-values are listed below:
c=o|r|g|a
This field sets the color of the LED. The 4 choices are:
o = off
r = red
g = green
a = amber
p=n[b]|s[b]|f[b]|d[b]|u[d]
This field sets the blinking pattern of the LED. The 4 choices are:
nb = no blink (steady on or off)
sb = slow blink (1s on and 1s off)
fb = fast blink (100ms on and 100ms off)
ud = user-defined (according to the contents of the u field)
u=on/off/on/off...
This is a user-defined blinking pattern used only when p = ud. It consists of up to 4 pairs of on/off duration
in seconds with up to 2 deciaml places; each value is separated by a forward slash (/).
Example 1: c=r;p=sb
Color is red and slow blink
Example 2: c=o
LED is off
Example 3: c=g
Color is green and steady on
Example 4: c=a;p=ud;u=.1/.1/.1/.1/.1/.9
Color is amber and blink with the pattern (100ms on, 100ms off, 100ms on, 100ms off,
100ms on, 900ms off).