Empire Comfort Systems DVLT series Installation Instructions And Owner's Manual page 45

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

PREMIUM MULTIFUNCTION REMOTE OPERATION INSTRUCTIONS
Countdown Timer
The Countdown Timer Mode allows the control to operate the unit
for up to 3 hours, in 10-minute increments. It can be operated in
either the Manual or Thermostat Modes.
1.
To enter Timer Mode, press and release the TIMER button.
The Timer icon will flash.
2.
Press the UP or DOWN button to set the running time, in
10-minute increments. Press and release the SET button. The
timer will run for the set time duration.
3.
Pressing the TIMER button while in Timer Mode will terminate
the Timer operation. The Timer operation will also terminate if
the MODE button is cycled to off.
Thermostat Mode
The unit is placed in Thermostat Mode using the MODE button.
Placing the unit in Thermostat Mode will activate the numbers in
the smaller window on the LCD screen.
1.
Press the UP or DOWN button to change the thermostat set
temperature. When the desired set temperature appears,
press and release the SET button to set.
2.
If the SET button is not pressed, the set temperature will au-
tomatically be set after 5 seconds.
3.
The Thermostat Mode can be de-activated by pressing the
MODE button.
Thermostatic Flame Modulation
This control can perform Main Flame Modulation using the Ther-
mostat. The control will shut the unit off when the room tempera-
ture reaches 2° above set temperature. The Thermostat will auto-
matically modulate the main flame as follows:
2° above set temperature
1° above set temperature
at set temperature
1° below set temperature
2° below set temperature
3° below set temperature
4° below set temperature
5° below set temperature
Manual Flame Modulation – Main Flame
To change the Flame Level manually, press the FLAME MAIN
button. The current level will show in the MAIN box on the LCD
screen.
1.
Press the UP or DOWN button to change the Flame Level.
2.
When the unit is turned on, whether in Manual, Thermostatic,
or Program Mode, the Main Flame will automatically ignite at
the High (7) setting. After 5 seconds, the flame will default to
the previous setting.
31259-3-0114
Manual Flame Modulation - Rear Flame
Feature not available.
Fan Control
The unit must be ON to operate the Fan.
The Fan will turn on after 5 minutes of operation. Once the Fan
comes on, it can be controlled using the FAN button.
1.
2.
3.
Accent Light
Not available on all models
The unit does NOT have to be on to operate the lights.
Lights are controlled by the LIGHTS button on the transmitter.
1.
2.
Continuous Pilot
The unit can be changed from Intermittent Pilot Ignition (IPI), to
Continuous, or standing, pilot.
1.
OFF
Flame Level 1
2.
Flame Level 2
Flame Level 3
3.
Flame Level 4
Flame Level 5
Flame Level 6
Flame Level 7
Press the FAN button, and the fan icon and speed will appear
on the LCD screen.
Press the UP or DOWN button to control the fan speed (0-6).
Press the DOWN button until 0 Level is reached to turn the
Fan off.
The fan will run for 12 minutes after the unit is shut off in any
mode. The fan may not be controlled during this period.
Press the LIGHTS button and the light icon and intensity level
will appear on the LCD screen.
Press the UP or DOWN button to set the light intensity level.
Press SET, or wait 7 seconds, and the light intensity setting
will be established.
To place the unit in continuous pilot mode, press and release
the PROG/TIME and the FLAME MAIN buttons simultane-
ously. Continuous Pilot will appear on the LCD screen.
Repeat the simultaneous PROG/TIME and FLAME MAIN
push to place the unit back in IPI mode.
This feature can also be activated by the Continuous Pilot
(On/Off) switch on the Main Module.
Page 45