Selecting Appliance Location; Clearances To Combustibles - Heat & Glo TIARAII-BK-B Owner's Manual

Direct vent room heater
Hide thumbs Also See for TIARAII-BK-B:
Table of Contents

Advertisement

3
Appliance Location and Clearances
NOTE:
·
Illustrations re ect typical installations and are FOR
DESIGN PURPOSES ONLY.
·
Illustrations/diagrams are not drawn to scale.
·
Actual installation may vary due to individual design
preference.
A. Selecting Appliance Location
When selecting a location for your appliance it is important
to consider the required clearances to wall (see Figure 3.1).
NOTE: For actual appliance dimensions refer to
Section 12.
B. Clearances to Combustibles
F
B
A
"A" measurement is from
appliance top, not side
Figure 3.1
Model
Tiara II B
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on
flooring surfaces.
G
D
E
A
90˚ off top up and out ceiling
A
B
5-1/4
1/4
Inches
133
6
9-1/2
Millimeters
Heat & Glo • TIARA II-B • 7011-148 Rev. L • 6/14
H
C
C
D
E
F
3/8
54
36
40
1372
914
1016
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traf c areas.
WARNING
Fire Risk.
Locate and install appliance to all
clearance speci cations in manual.
C
G
A
H
Top of
Side of
G
pipe
pipe
31-3/4
1-1/2
1
806
76
25
WARNING
Fire Risk.
Odor Risk.
Tipping Risk
Install appliance on a stable, level platform/
oor strong enough to support appliance
without tipping.
USE wood ooring, ceramic tile, brick hearth
or high pressure laminate ooring applied
directly over the sub- ooring material.
A
Inside
Outside
corner
wall vent
9
229
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heat & glo tiaraii-br-bHeat & glo tiaraii-ces