Heat & Glo TIARAII-BK-B Owner's Manual

Direct vent room heater
Hide thumbs Also See for TIARAII-BK-B:
Table of Contents

Advertisement

Quick Links

TIARA II-B
DIRECT VENT ROOM HEATER
Models:
TIARAII-BK-B
TIARAII-BR-B
TIARAII-CES
• Important operating and
maintenance instructions
included.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance.
Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the re department.
• Installation and service must be performed
by a quali ed installer, service agency, or the
gas supplier.
Installation and service of this appliance should be
performed by quali ed personnel. Hearth & Home
Technologies suggests NFI certi ed or factory-trained
professionals, or technicians supervised by an NFI
certi ed professional.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and
follow these instructions
for safe installation and
operation.
• Keep children away
• CAREFULLY SUPERVISE children in the same room as
• Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
ammable materials.
• Keep clothing, furniture, draperies and other combustibles
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber or gas
See Table of Contents for additional Commonwealth of Mas-
sachusetts requirements.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated on
the rating plate.
Heat & Glo • TIARA II-B • 7011-148 Rev. L • 6/14
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT GLASS WILL CAUSE
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
appliance
away.
tter.
O-T
O-T L
Tested and
Portland
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
BURNS.

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo TIARAII-BK-B

  • Page 1 DIRECT VENT ROOM HEATER O-T L Tested and Portland Listed by Oregon USA Models: OMNI-Test Laboratories, Inc. TIARAII-BK-B TIARAII-BR-B TIARAII-CES CAUTION DO NOT DISCARD THIS MANUAL • Read, understand and • Important operating and • Leave this manual with follow these instructions...
  • Page 2 Read this manual before installing or operating this appliance. Please retain this owner's manual for future reference. Congratulations This Owner's Manual should be retained for future reference. Congratulations on selecting a Heat & Glo gas appliance - We suggest that you keep it with your other important an elegant and clean alternative to wood burning appliances.
  • Page 3: Table Of Contents

    Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. •...
  • Page 4: Section 1: Listing And Code Approvals

    Listing and Code Approvals C. Speci cations A. Appliance Certi cation MODEL Tiara II B Maximum Input Minimum Input Ori ce Size Model (US or Canada) LABORATORY OMNI-Test Laboratories, Inc. Top Vent 061-S-44b-5 TYPE Vented Gas Fireplace Heater Tiara II B (NG) 38,500 27,000 .120...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    Inspection NOTE: The following requirements reference various The state or local gas inspector of the side wall horizontally Massachusetts and national codes not contained in this vented gas fueled equipment shall not approve the installa- document. tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with G.
  • Page 6: Section 2: Getting Started

    Getting Started C. Inspect Appliance & Components A. Design & Installation Considerations Heat & Glo direct vent gas appliances are designed to oper- ate with all combustion air drawn from outside of the building WARNING and all exhaust gases expelled to the outside. No additional air source is required.
  • Page 7: Selecting Appliance Location

    Appliance Location and Clearances NOTE: WARNING · Illustrations re ect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: · Illustrations/diagrams are not drawn to scale. • Around air openings · Actual installation may vary due to individual design •...
  • Page 8: Vent Termination Minimum Clearances

    Termination Locations A. Vent Termination Minimum Clearances HORIZONTAL OVERHANG WARNING 2 FT. 20 INCHES MIN. Fire Risk. VERTICAL MIN. WALL Explosion Risk. LOWEST DISCHARGE Maintain vent clearance to combustibles OPENING as speci ed. GAS DIRECT VENT TERMINATION CAP • Do not pack air space with insulation or other materials.
  • Page 9 (See Note 2) U.S. (3 FT) Electrical Service J or K = VENT TERMINAL = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED = 3 ft. (U.S.A.) = 12 inches ..... clearances above grade, veran- 6 ft. (Canada) ..clearance to a mechanical (See Note 1) da, porch, deck or balcony (powered) air supply inlet...
  • Page 10: Section 5: Vent Information

    Vent Information A. Venting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: CAUTION • Hearth & Home Technologies (HHT) ALL vent con guration speci cations MUST be followed. •...
  • Page 11: How To Use The Vent Graph

    How to Use the Vent Graph Venting Guidelines • The minimum vertical rise off the top before an elbow is 2 ft. Measure the distance from the top of appliance to the (609 mm). center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis •...
  • Page 12: Horizontal Termination

    F. Horizontal Termination WARNING Fire Risk. Type A - Up & Out Installation Exhaust Fume Risk. Impaired Performance of Appliance. 90° ELBOW • Ensure vent components are locked together correctly. CENTER LINE • Pipe may separate if not properly joined. TERMINATION CAP PIPE LENGTH WALL THIMBLE/...
  • Page 13 Step 3. For installations using a round support box/wall thimble WOOD (check pipe manufacturer's instructions), mark the wall for SCREW a 10 in. x 10 in. (254mm x 254mm) square hole. The center of the square hole should line up with the center line of the horizontal pipe, as shown in Figure 5.5.
  • Page 14: Vertical Termination

    VINYL SIDING WARNING Apply sealant to all four sides Do NOT connect a pipe section to a termination cap without using the telescoping ue section found on the termination cap. SCREWS WARNING Bolt horizontal top to vinyl standoff Burn Risk. •...
  • Page 15 Step 3. To install the round support box/wall thimble cover in a flat WARNING ceiling, cut a 10 in. (254mm) square hole in the ceiling, centered on the hole drilled in Step 2. Frame the hole as Fire Risk. shown in Figure 5.13. Explosion Risk.
  • Page 16 Step 9. Twist-lock the vent cap and seal. CAP AND STORM Shingles overlap on COLLAR NOT SHOWN Note: For multi-story vertical installations, a ceiling firestop top edge of flashing FOR CLARITY is required at the second floor, and any subsequent floors (Figure 5.16).
  • Page 17 2. Cathedral Ceiling Step 1. Follow installation Steps 1 and 2 under vertical installation section, page 16. Step 2. Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box. Cut the hole 1/8 in. (3mm) larger than the support box outline. Step 3.
  • Page 18 Step 4. 3. Class A Metal Chimney Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. Drill four 1/8 in. (3mm) diameter holes through the top adapter, and into the chimney top.
  • Page 19 4. Existing Masonry Chimney Type A & B Co-Axial to Co-Linear Chimney Liner Termination Cap Chimney Liner Termination Cap 30 ft. (9m) of 3 in. (76mm) Flex Liner Exhaust Section This section of the 3 in. (76mm) chimney must be Flex Liner Co-Axial to sealed...
  • Page 20 CAUTION Cut and bend flashing as needed to fit Ensure that existing chimney is functionally sound and clean. • Have inspection done by qualified chimney sweep or professional installer BEFORE converting to direct vent appliance. Step 1. Before cutting any holes, assemble the desired sections of direct vent pipe to determine the center of the masonry penetration.
  • Page 21 6 in. (152mm) diameter Flex Liner opening in masonry wall Flex Coupler Sheet Metal Screws Retro Connector (3) Masonry Bolts (Not included) Figure 5.27 Figure 5.29 Step 8. Secure the top adapter to the flashing. Use three sheet Step 10. metal screws through the side of the top adapter into the Slide wall thimble cover over retro connector and secure with flange on the flashing (Figure 5.28).
  • Page 22: Section 6: Gas Information

    Gas Information A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali ed Loosen Left Screw technician using Hearth &...
  • Page 23 Mounting Screws 5/32 in. Allen wrench Pressure Regulator Tower Diaphragm Use a 5/32 in. Allen wrench to remove the pilot injec- Figure 6.4 tor. Replace pilot injector with the one supplied with the appliance (#35 for Propane, #62 for Natural Gas). Replace pilot hood, snapping into position.
  • Page 24: Gas Pressures

    Pressure requirements for appliance are shown in the table below. Minimum pressures must be met when other WARNING household gas appliances are operating. Fire Risk. Explosion Risk. PRESSURE Gas Leak Risk. Minimum Inlet Pressure 5 inches w.c. 11 inches w.c. •...
  • Page 25 C. Gas Connection (Cont’d) Leak test all gas line joints and the gas control valve prior WARNING to and after starting the appliance. Fire Risk. Before making the gas connection, ensure that the appliance Do NOT change the valve settings. •...
  • Page 26: Section 7: Electrical Information

    Electrical Information A. Recommendation for Wire Ensure the thermostat is mounted level for accurate readings. See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch. The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air. 10.
  • Page 27: Ignition Module Access And Battery Replacement

    PILOT ASSEMBLY IGNITON MODULE TPTH BLACK ON / OFF SWITCH BLACK VALVE REMOTE SWITCH Figure 7.1 CAUTION CAUTION Shock hazard. Label all wires prior to disconnection when servicing controls. • Replace damaged wire with type 105 Wiring errors can cause improper and dangerous operation. rated wire.
  • Page 28: Section 8: Appliance Setup

    Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the rebox. B. Top to Rear Vent Conversion KIT CONTENTS: Rear vent grille: NG ori ce (.111); LP ori ce (.063) TOOLS REQUIRED: Power drill; #2 Phillips bit; high-temp sealant (optional).
  • Page 29: Damper Adjustment

    2. Top Vent Installations CLOSED OPEN Shown Fully Open Insert inner collar adapter to rear ue vent. Figure 8.7 Locate the damper adjustment on the intake Figure 8.10 plenum, accessing through the appliance front. Adjustor is centered at the top of the appliance. Loosen screws using a Phillips head screwdriver.
  • Page 30: Leg Leveling System

    E. Leg Leveling System TABS Install left and right side panels. Fold tabs over Figure 8.16 Thread Allen bolts through nuts until ush. The Figure 8.12 on left and right sides to hold panels in place. Allen bolts and nuts are included in the component pack inside the appliance rebox.
  • Page 31: Positioning The Logs

    G. Positioning the Logs I. Accessories Install approved accessories per instructions included with accessories. Refer to Section 12 for appropriate accesso- ries. WARNING Shock or Fire risk. Use ONLY optional accessories approved for this appliance. • Using non-listed accessories voids warranty. •...
  • Page 32 J. Optional Blower (Cont’d) WING NUT BLOWER Slide temperature sensor switch/bracket Figure 8.25 WING assembly onto the 10-32 screw located on the left underside of the appliance. Secure the bracket assembly CONTROL KNOB with the wing nut provided. TEMPERATURE CONTROL SENSOR SWITCH Disconnect the two wire ends connected together on...
  • Page 33: Glass Replacement

    VARIABLE SPEED SWITCH PLUG INTO 120V EXISTING OUTLET AUX / REMOTE RECEPTACLE GROUND BLOWER RECEPTACLE TEMPERATURE SENSOR SWITCH Figure 8.28 K. Glass Replacement CAUTION Turn appliance OFF and let cool down before replac- ing the glass. Handle glass assembly with care. Remove the front by lifting upwards 1/2 in.
  • Page 34: Warming Shelves Installation

    L. Warming Shelves Installation Kit Contents: (2) Warming shelves, (2) brackets, and (4) 1/4 in. Phillips head screws. Tools Required: Phillips head screwdriver. Align bracket to rebox and gently tighten the Figure 8.32 screw to hold it in place. Reassemble the appliance. Remove warming shelves and hardware from Figure 8.29 packaging.
  • Page 35: Section 9: Operating Instructions

    Operating Instructions A. Before Lighting Appliance WARNING Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to bodily injury, or even death.
  • Page 36: Lighting Appliance

    C. Lighting Appliance FOR YOUR SAFETY READ BEFORE LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life A. This appliance has a pilot that must be lit manually. When lighting the pilot, follow these instructions exactly. B.
  • Page 37: After Appliance Is Lit

    D. After Appliance is Lit CAUTION Initial Break-in Procedure • Prevent accidental appliance operation when not When you light your appliance, you may notice that it pro- attended. • Unplug or remove batteries from remote control if absent duces heat which does have an associated odor or smell. If or if appliance will not be used for an extended period of you feel this odor is excessive it may require the initial three time.
  • Page 38: Section 10: Troubleshooting

    Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali ed service person in the diagnosis of a problem and the corrective action to be taken.
  • Page 39 Symptom Possible Cause Corrective Action 3. (Continued) c. Defective valve. Turn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter at the thermopile terminals. The millivolt meter should read greater than 125mV. If the reading is acceptable, and if the burner does not come on, replace the gas valve.
  • Page 40: Maintaining And Servicing Appliance

    Maintaining and Servicing Appliance Although the frequency of your appliance servicing and CAUTION maintenance will depend on use and the type of installation, a quali ed service technician should perform an appliance check-up at the beginning of each heating season. Handle glass assembly with care.
  • Page 41: Maintenance Tasks

    A. Maintenance Tasks Inspect Maintenance Tasks Doors 1. Inspect for scratches, dents or other damage and repair as necessary. 2. Verify no obstructions to air ow. 3. Verify maintenance of proper clearance to combustible household objects. Gasket Seal, Glass 1. Inspect gasket seal and its condition. Assembly and Glass 2.
  • Page 42: Section 12: Reference Materials

    Reference Materials Dimensions are actual appliance dimensions. Use for A. Appliance Dimension Diagram reference only. For clearances to combustibles refer to Section 3. NOTE: Diagrams show gas appliance equipped with optional Blower, Part #GFK-160A. Location Inches Millimeter Location Inches Millimeter 41-3/4 1060 22-1/4...
  • Page 43: Vent Components Diagram

    B. Vent Components Diagram 6-3/8 in. (162mm) 6-1/2 in. (165mm) 14 in. 9-1/4 in. 356 mm (235mm) 6-1/2 in. (165mm) 9-5/8 in. 6-3/8 in. (244mm) 10-9/16 in. (162mm) 6-5/8 in. 269 mm (168mm) SLP45-BK SLP-CCS-BK Cathedral Ceiling Support Box-Black 6-5/8 in. (168mm) 9-5/8 in.
  • Page 44: Vent Components List

    C. Vent Components List Description HHT SLP Simpson ® M= Multi Pack (6) Dura-Vent DirectVent Pro 4” Pipe Length, Galvanized SLP4M ” 4 ” 6 ” 6 ” 9 ” 9 12” Pipe Length, Galvanized SLP12M 46-DVA-12 ” 2 ” 8 ”...
  • Page 45 C. Vent Components List (continued) Simpson HHT SLP ® Description Dura-Vent M= Multi Pack (6) DirectVent Pro ° 0 ° 0 ° 0 ° 0 Adjustable Flashing, 0/12-6/12 SLP-RF6M 46DVA-F6 Adjustable Flashing, 7/12-12/12 SLP-RF12M 46DVA-F12 c i t ” 2 Attic Insulation Shield, Adjustable 11”-20”...
  • Page 46: Service Parts & Accessories

    E. Limited Lifetime Warranty Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 47 E. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. •...
  • Page 48: Contact Information

    F. Contact Information Heat & Glo, a brand of Hearth & Home Technologies 7571 215th St, Lakeville, MN 55044 www.heatnglo.com Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com.

This manual is also suitable for: