Selecting Appliance Location; Clearances To Combustibles - Heat & Glo MISSION-BAY Owner's Manual

Direct vent room heater
Table of Contents

Advertisement

3
Appliance Location and Clearances
NOTE:
·
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
·
Illustrations/diagrams are not drawn to scale.
·
Actual installation may vary due to individual design
preference.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to wall (see Figure 3.1).
NOTE: For actual appliance dimensions refer to
Section 12.
B. Clearances to Combustibles
H
B
C
A
Model
Mission
Bay
Figure 3.1
It is permissable to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
July 12, 2006
G
D
A
A*
10
10
Inches
254
254
Millimeters
Heat & Glo · Mission Bay · 250-7512F
Fire Risk
Provide adequate clearance:
• Around air openings
• To combustibles
• For service access
Locate appliance away from traffic areas.
F -Alcove height
D
A*
B
C
D
2
6
2
51
152
51
2134
Fire Risk.
Odor Risk.
Tipping Risk
WARNING
WARNING
Fire Risk.
Locate and install appliance to all
clearance specifications in manual.
E
A*
E
F
G
84
19
36
483
914
WARNING
Install appliance on a stable, level platform/
floor strong enough to support appliance
without tipping.
USE wood flooring, ceramic tile, brick hearth
or high pressure laminate flooring applied
directly over the sub-flooring material.
H
40
1016