INSTALLATION AND OPERATION

INSTRUCTIONS
MODEL: ST-HVBI-AU
AUSTRALIAN GAS ASSOCIATION APPROVED
APPROVAL NUMBER 6027
THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED
BY HOMEOWNER FOR OPERATION AND MAINTENANCE.
HEAT & GLO, a brand of Hearth & Home Technologies Inc.
20802 Kensington Blvd., Lakeville, MN 55044, USA • (952) 985-6000
THIS PRODUCT MAY BE COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS:
(United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073,
5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226,
6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408; (Australia) 543790;586383;
(Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo ST-HVBI-AU

  • Page 1: Installation And Operation

    6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408; (Australia) 543790;586383; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 2 Heat & Glo, a brand of Hearth & Home Technologies, Inc. Heat & Glo Quality Systems 20802 Kensington Blvd., Lakeville, MN 55044, USA registered by SGS ICS Copyright 2006 • Printed in U.S.A. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 3: Table Of Contents

    Removal of Components for Service ..........31 Parts Replacement ................31 Adjustments and Replacement Parts ..........31 Troubleshooting .................. 32 4.0 REPLACEMENT PARTS................35 Limited Warranty ..................37 Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 4: Installation Instructions

    36-3/16 in. (610m) (121mm) (114mm) (919.3mm) TOP STANDOFFS FLUE COLLAR FLUE COLLAR LOUVER ACCESS DOOR GAS CONTROLS & LABELS GAS LINE ELECTRICAL ACCESS ACCESS Figure 1. Diagram of ST-HVBI-AU Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 5: Locating The Heater

    64 ..... 2 1/2 Ceiling* 787 ....31 * The clearance to the ceiling is measured from the top of the unit, excluding the standoffs (see Figures 1 and 2). Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 6: Framing The Heater

    51mm x 102mm (2 in. x 4 in.) lumber or heavier. 1.21 M (47-5/8 in.) 1.08 M (42-1/2 in.) 584 mm (23 in.) 909 mm (35-3/4 in.) 1.37 M (54 in.) Figure 3. Framing Dimensions Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 7 4. See Appendix J, Figure J1(a) and J2(a) for clearances required from a flue terminal to a LP Gas cylinder. A flue terminal is considered to be a source of ignition. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 4. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 8 (1/2 in.) TYP 320mm (12-9/16 in.) NOTE: PIPES OVERLAP 32mm (1-1/4”) AT EACH JOINT. Figure 5. DVP-Series Direct Flue Component Specifications (127mm (5”) inner pipe / 203mm (8”) outer pipe) Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 9: Flue System Approvals And Installation

    STORM COLLAR TERMINATION ROOF FLASHING HORIZONTAL TERMINATION WALL FIRESTOP PIPE LENGTH 90 DEGREE ELBOW Terminations Kits CEILING FIRESTOP DVP-TRAP DVP-TVHW SERIES Figure 6. Flue System Components and Termination Kits Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 10 STRAIGHT UP VERTICAL FLUEING V (FT.) 12.2M MAX. (40 FT.) Figure 7. STRAIGHT OUT HORIZONTAL FLUEING Max. Run 610 mm (24 in.) Figure 8. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 11 15’ MAX. (4.5m) 5’ MIN. (1.5m) 10' MAX. (3.0m) V + H = 40’ MAX. (12.2m) V + H = 40’ MAX. (12.2m) Figure 10. Flueing with One 90° Elbow Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 12 6’ MAX. (1.83m) 4' MIN. (1.22m) 8' MAX. (2.4m) 5’ MIN. (1.5m) 10' MAX. (3.0m) V + V + H = 40’ MAX. (12.2m) Figure 11. Flueing with Two 90° Elbows Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 13 V + H + H = 40’ MAX. (12.2m) H + H = 15’ MAX. (4.5m) H + H = 10’ MAX. (3.0m) Figure 13. Flueing with Two 90° Elbows Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 14 + H + H = 36’ MAX. (10.9) H + H = 12’ MAX. (3.6m) H + H = 8’ MAX. (2.4m) Figure 14. Flueing with three 90° elbows Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 15 5’ MIN. (1.5m) 10' MAX. (3.0m) + H + H = 36’ MAX. (10.9m) V+ V H + H = 10’ MAX. (3.0m) Figure 15. Flueing with three 90° elbows Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 16 • Overlap pipe slip sections at least 1-1/2 inches (38.1mm). • Use pilot holes for screws. • Screws must not exceed one inch (25.4mm) long. • Pipe may separate if not properly joined. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 17 For elbows that are changing the flue direction, two screws minimum should be put in the outer flue at the joint to prevent the elbow from rotating. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 18 12" 10" (254mm) 10" (254mm) Figure 22. 10" x 12" Hole and Flue Pipe CHIMNEY HOLE EXISTING CEILING JOISTS FRAMING MEMBERS CEILING Figure 24. Hole & New Framing Members Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 19 CEILING FIRESTOP Figure 26. Attic Firestop WARNING: FLUEING TERMINALS SHALL NOT BE RECESSED INTO A WALL OR SID- ING. FLUE TERMINATION CLEARANCES MUST BE FOLLOWED TO AVOID FIRE DANGER. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 20 Figure 29. Minimum Height from Roof to Lowest Discharge Opening WARNING: FOLLOWING NATIONAL REG- ULATIONS AND CODES OF PRACTICE FOR MINIMUM CLEARANCES FROM GAS TERMINALS, AND PLACEMENT OF GAS TERMINAL. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 21: Connecting The Gas Supply

    IGNITION MODULE (6V) 6VDC GROUND NEUTRAL BATTERY PORT PLUG IN THERMOCOUPLE ON/OFF BLOCK SWITCH (CONNECTED TO BACK OF VALVE) VALVE GAS LINE CONNECTED TO BACK OF VALVE Figure 31. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 22: Blower Wiring

    Figure 32 shows the fan, switches, and fan wiring diagram. Figure 33 shows the wire connection detail. BLACK BROWN (HOT) BROWN BLACK BROWN (NEUTRAL) BLUE BLUE BLUE Figure 33. Wire Connection Detail Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 23: Mantel Clearances

    1010 INSIDE EDGE OF DRESS GUARD OPENING DRESS GUARD NOTE: ALL DIMENSIONS ARE SHOWN IN MILLIMETERS Figure 34. HIGH TEMP (300 F. 150 C. MIN.) SEAL JOINT Figure 35. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 24: Log Installation

    LOG #2 (SRV2068-701): Locate log #2 in left front corner of the log grate using bottom grooves for placement. Push log against grate tabs on first and second bars. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 25 Place log #5 on top of flat spot on log #1 and against the inside of log #2. Be careful not to reposition log #2 when placing this log. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 26 LOG #6 (SRV582-705): Position log #6 on top of the groove in log #3 with the forked end resting on the grate assembly as shown. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 27: Installer Testing

    This noise is similar to one that a furnace or heat duct may pro- duce and does not affect the operation or longevity of the heater. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 28: Operating Cautions

    Do not strike or slam the glass door. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 29: Safety And Lighting Information

    OFF (as shown in Figure 39) to shut off manually. The switch must be returned to the ON position prior to operation once power is restored. SWITCH IS SHOWN IN "ON" POSITION Figure 39. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 30: Fan Operation

    Clean all for- eign materials from top of burner. Check to make sure that the burner orifice is clean. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 31: Removal Of Covers For Servicing

    Remove two pilot bracket retaining screws (see Figure 41.) Slide the burner away from the burner orifice. PILOT BRACKET RETAINING SCREWS Figure 41. CAUTION: ALL SCREWS WHICH WERE REMOVED MUST BE REPLACED. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 32 4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and flashing remains intact. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 33: Troubleshooting

    Ignitor gap is too large. Verify that spark gap from ignitor to pilot hood is .43 cm. c. Module is not grounded. Verify module is securely grounded to metal chassis of fireplace. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 34 3. Be sure glass is tighened properly on unit, particularly on top corners. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 35: Replacement Parts

    ST-HVBI-AU 4.0 REPLACEMENT PARTS (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4/06 Ending Manufacturing Date: ______ 20 Log set Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 36 C o nve rs io n K it N G P 2 N -S TH V B I-A U C o nve rs io n K it L P N 2 P -S TH V B I-A U Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...
  • Page 37: Limited Warranty

    HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications and prices. It also reserves the right to discontinue styles and products. Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06...