internal programming jumper

light flash jumper
This jumper is used to determine the light flash output. In the (+) position, the on-board relay is enabled and
the unit will output (+)12V on the H1/2 WHITE wire. In the (-) position, the on-board relay is disabled. The H1/2
WHITE wire will supply a (-) 200 mA output suitable for driving factory parking light relays. To access the jumper,
open the control module.
NOTE: For parking light circuits that draw 10 amps or more, the internal jumper must be switched
to a (-) light flash output. P/N 8617 or a standard automotive SPDT relay must be used on the
H1/2 light flash output harness wire.