Unlocking The Sfp Module Latch - Wire Variety; Pull-Rings For Removing A Controller - IBM TotalStorage FAStT600 Installation And User Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage FAStT600:
Table of Contents

Advertisement

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wire tab
Protective cap
o
90
Figure 51. Unlocking the SFP module latch - wire variety
c. With the SFP latch in the unlocked position, extract the SFP module.
v For SFP modules that contain plastic tabs, slide the SFP module out of
the port.
v For SFP modules that contain wire tabs, grasp the wire latch and pull
the SFP module out of the minihub port.
d. Replace the protective cap on the SFP module.
e. Place the SFP module into a static-protective package.
f. Replace the protective cap on the port.
8. Remove the RAID controller to be upgraded, as follows:
a. Push down on the latch (centered above the RAID controller). Pull both
levers at the same time out of the locked position.
b. Grasp the pull-rings (see Figure 52), then pull on the levers and remove
the RAID controller.
Figure 52. Pull-rings for removing a controller
9. Unpack the new RAID controller with the 1-GB memory. Verify that the battery
is in the controller by opening the FAStT600 controller CRU, using step 6
through step 9 of "Replacing the battery in the RAID controller" on page 92.
If there is no battery in the new FAStT600 controller, remove the battery from
the old controller and install it in the new controller.
SFP module
Chapter 5. Installing and replacing components
65

Advertisement

Table of Contents
loading

Table of Contents