Location Of Sfps And Fiber-Optic Cables; Unlocking The Sfp Module Latch - Plastic Variety - IBM TotalStorage FAStT600 Installation And User Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage FAStT600:
Table of Contents

Advertisement

|
|
|
|
|
|
|
|
|
|
|
|
64
IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User's Guide
SFP module
Fiber-optic
cable
Figure 49. Location of SFPs and fiber-optic cables
After removing the fibre-channel cables, insert the protective caps.
7. Use the following procedure to remove the SFPs from the RAID controller to
be upgraded.
a. Remove the LC-LC fibre-channel cable from the SFP module. For more
information, see "Handling fiber-optic cables" on page 33.
b. Unlock the SFP module latch:
v For SFP modules that contain plastic tabs, unlock the SFP module latch
by pulling the plastic tab outward 10°, as shown in Figure 50.
Plastic tab
Protective cap
o
10
Figure 50. Unlocking the SFP module latch - plastic variety
v For SFP modules that contain wire tabs, unlock the SFP module latch by
pulling the wire latch outward 90°, as shown in Figure 51 on page 65.
Raid controller
SFP module

Advertisement

Table of Contents
loading

Table of Contents