For information about the LEDs on the front of the storage server, see:
v Figure 43
v Table 7
For information about the LEDs on the back of the storage server, see:
v Figure 45 on page 54
v Table 8 on page 52
v Table 9 on page 54
General-system-
error LED
Power-on LED
Figure 43. Storage server LEDs (front)
Table 7. Storage server LEDs (front)
LED
Color
Drive active
Green
Drive fault
Amber
Power
Green
General system
Amber
error
Locator LED
Drive fault LED
Operating states
v On - Normal operation.
v Flashing - The drive is reading or writing data.
v Flashing every 5 seconds - The drive has not
spun up or the drive is bad.
v
Off - One of the following situations has occurred:
– The storage server has no power.
– The drive is not properly seated in the storage
server.
v Off - Normal operation.
v Flashing - The storage-management software is
locating a drive, logical drive, or storage
subsystem.
v On - The drive has failed, or a user failed the drive.
v On - Normal operation.
v Off - One of the following situations has occurred:
– The storage server has no power.
– Both power supplies have failed.
– There is an over-temperature condition.
v Off - Normal operation.
v On - A storage server component has failed