System Features Menus; Feature Descriptions - Avital 2101L Installation Manual

Car security
Hide thumbs Also See for 2101L:
Table of Contents

Advertisement

System Features Menus

Feature
Default LED ON Setting
Number
(Press Channel 1)
1
Ignition-controlled door lock ON
2
Ignition-controlled door unlock ON
3
Ignition-controlled domelight ON
4
0.8 second door lock pulses
5
Double pulse unlock OFF
6
Double pulse lock OFF
7
Comfort closure OFF
8
Code Hopping ON
Note: Factory default settings are shown in BOLD.
Note: For feature number 1-4, the 3.5 second door lock pulse
setting the siren chirps twice, for the 0.4 second door lock
pulse setting the siren chirps three times.

Feature Descriptions

The features of the system are described below.
1 IGNITION CONTROLLED DOOR LOCK ON/OFF: When turned on, the doors will lock three
seconds after the ignition is turned on.
2 IGNITION CONTROLLED DOOR UNLOCK ON/OFF: When turned on, the doors will
unlock when the ignition is turned off.
3 IGNITION CONTROLLED DOMELIGHT: If turned on, the system will turn on the domelight
for 30 seconds when the ignition is turned off. The domelight supervision output (H1/4) wire must
be connected to an optional relay as described in the Primary Harness Wire Connection Guide.
4 DOOR LOCK PULSE DURATION: Some European vehicles, such as Mercedes-Benz and Audi,
require longer lock and unlock pulses to operate the vacuum pump. Programming the system to
provide 3.5 second pulses will accommodate the door lock interface in these vehicles. The default
setting is 0.8 second door lock pulses. For some vehicles a 0.4 second pulse duration is required, this
11
LED OFF Setting
(Press Channel 2)
Ignition-controlled door lock OFF
Ignition-controlled door unlock OFF
Ignition-controlled domelight OFF
3.5 second door lock pulses/0.4 sec.
Double pulse unlock ON
Double pulse lock ON
Comfort closure ON
Code Hopping OFF
©
2008
Directed Electronics